GDCR3000 Digital Earth Resistance Tester--Thanks for choosing HV HIPOT

GDCR3000 Digital Earth Resistance Tester

Application

GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement.

GDCR3000 Digital Earth Resistance Tester has a unique function of wire resistance verificationmore accurate on measuring on-site low value earth ground resistance, which can avoid error caused by resistance change due to prolonged usage of testing wire; avoid error caused by testing wire that is failed to be fully inserted into tester interface or by poor contact; avoid error caused by users’ replacing or lengthening testing wires.

GDCR3000 Digital Earth Resistance Tester is composed of host machine, monitoring software, testing wires, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 400 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, with the maximum, minimum, and mean indicators, with alarm settings and alarm indicator, and with the functions like historical data access, reading, preservation, report forms, printing and so on.

Specification

Functions

Earth resistance measurement, earth voltage measurement,Low resistance measurement

Power

supply

DC 9V (Zn-Mn dry battery R14S 1.5V 6 pieces,Continuous 300 hrs )

Methods of Measurement

Earth resistance :Rated current pole changing method; test current : 3mA Max, 820Hz; Earth voltage : Average rectifier

Dispaly

model

4 digital LCD display,Blue-screen backlight

Indicator light

LED indicator flash during test,LCD count down display

LCD

dimension

124mm×67mm

Dimension

Instrument -- 215mm×190mm×95mm,1443g( included battery)

Test leads -- 1.6m*2pieces , 20m*1 piece , 10m*1 piece , 5m* 1 piece , 847g

Ground rop-- φ10mm×150mm*2pieces , φ10mm×150mm ,468g

Carrying bag: 915g

Earth

Resistance

Test Range: 0.01Ω~20Ω( resolution--0.01Ω) ,0.1Ω~200Ω( resolution --0.1Ω),1Ω~2000Ω( resolution --1Ω) ; accuracy :±1%reading±3dgt

Earth

Voltage

AC 0~600V ; accuracy :±1%reading±3dgt

Test time

Earth voltage:about 3 times/second

earth resistance:about 5 second/time

Measure

times

Above 5000 times

Line voltage

Earth voltage:measure below AC 600V

RS232

connector

RS232 connector,Software monitoring,stored data can be uploaded to PC , storage and printed.

Communication cable

RS232 ,1.5m * 1 piece

Working

condition

-10 ℃ ~40 ℃ ;below 80%rh

Storage

condition

-20 ℃ ~60 ℃ ;below 70%rh

Over-load

protection

Measurement of earth resistance:E-P,E-C ; AC 280V/ 3 secs

Insulation

resistance

Above 10MΩ(between circuit and the shell , 500V)

Withstand

voltage

AC 3700V/rms(between circuit and the shell)

Electromagnetic property

IEC6 1010-4-3 ,electromagnetic field≤1V/m

Standards

IEC61010-1 , IEC1010-2-31 , IEC61557-1,5, IEC60529(IP54)