• 0
    • 0
    GD3126B 10kV Insulation Resistance Tester hits:

    Product Description


    GD3126B Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR) and polarization index (PI) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc.


    Features

    • Using microcomputer control, menu operation and large LCD screen dot matrix display with stable performance.
    • Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment.
    • Large capacity, can meet the requirements of high voltage, high resistance, large capacity load test.
    • With shockproof, moisture-proof and dust-proof structure, adapt to the harsh working environment.
    • User friendly, display accurate results and data change trends.
    • Perfect protection function, able to withstand impact of short circuit and the measured capacitance residual voltage.
    • Output high voltage can also be continuously adjusted.
    • Automatic measurement of R15, R60, R600, automatic calculation of absorption ratio, polarization index.
    • Maximum resistance measurement range is 0~20TΩ, automatic switching range.
    • Automatic measurement of ambient temperature, air humidity and test time.
    • Displays the test time, buzz tips at every 15 seconds, 5 minutes without operation will prompt shutdown.
    • Automatically discharge high voltage after measurement is completed, the discharge time is no more than 30 seconds.
    • Storage of 60 groups of measuring results, nonvolatility.
    • With RS232 serial interface, able to data communicate with computer.
    • With external printer, can print measuring results. (optional)
    • Able to detect leakage current Ix and absorption capacitance Cx. (Optional)


    Specifications

    Rated test voltage

    GD3126A(5kV)

    GD3126B(10kV)

    250 V, 500V, 1.0kV, 2.5kV, 5.0kV

    250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10.0kV

    Output voltage error

    ±5%

    Resistance range

    Upper limit

    500GΩ-10TΩ

    500GΩ-20TΩ

    Lower limit

    0.1MΩ

    0.1MΩ

    Accuracy class

    Class 5.0

    High voltage display error

    ±( 5%•Ux + 1d )

    Temperature measuring error

    ±0.5℃

    Humidity measuring error

    ±2%RH

    Short circuit current

    Approx. 6mA

    Voltage ripple

    <3%

      Insulation resistance

    > 500 MΩ (between test wire and case)

    Withstand voltage

    AC10.0kV 50Hz 1min (between test wire and case)

    Power supply

    14.8V lithium battery

    Battery service time after one charging

    30days 10times DAR & 5times PI test per day

    Working temperature and humidity

    0℃ ~ + 40℃   < 85%RH

    Storage temperature and humidity

    - 20℃ ~ + 50℃  < 90%RH

    Dimension (mm)

    325 (L)*250(W)*130(H)

    Weight

    3.7kg

    Resistance measuring error

    Voltage steps

    250 V

    500 V

    1.0 kV

    2.5 kV

    5.0 kV

    10.0 kV

    ±( 3%·Rx + 1d )

    1GΩ

    2GΩ

    4GΩ

    10GΩ

    20GΩ

    40GΩ

    ±( 5%·Rx + 1d )

    10GΩ

    20GΩ

    40GΩ

    0.1TΩ

    0.2TΩ

    0.4TΩ

    ±( 10%·Rx + 2d )

    100GΩ

    200GΩ

    0.4TΩ

    1TΩ

    2 TΩ

    4TΩ

    ±( 25%·Rx + 2d )

    500GΩ

    1TΩ

    2TΩ

    5TΩ

    10TΩ

    20TΩ



    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.