    GD6800 Capacitance and Dissipation Factor Tester hits:

    Product Description

    GD6800 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

     

    High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.



    Features

    • Touch LCD screen display.
    • Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
    • The instrument data can be exported through U disk, and can be used to view and manage the data through the software on PC.
    • Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
    • Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
    • The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
    • High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
    • LCR automatic measurement. Inductance, capacitance, resistance can be measured and displayed.
    • Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
    • No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
    • Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.




    Specifications


    Working condition

    -15~40

    RH<80%

    Anti-interference principle

    Frequency conversion

    Power supply

    AC 220V±10%

    Generator can be used.

    High voltage output

    0.5KV~10KV

    Every 0.1kV

    Accuracy

    2%

    Max. current    

    200mA

    Capacity

    2000VA

    Self-excitation power

    AC 0V~50V/15A

    45HZ/55HZ  47.5HZ/52.5HZ

    55HZ/65HZ  57.5HZ/62.5HZ

    Automatic dual frequency

    Resolution

    tgδ: 0.001%

    Cx: 0.001pF

    Accuracy

    ∆tgδ: ±(reading*1.0%+0.040%)

    ∆C x: ±(reading*1.0%+1.00PF)

    Measurement range

    tgδ

    Without limit

    C x

    15pF < Cx < 300nF

    10KV

    Cx < 60 nF

     5KV

    Cx < 150 nF

     1KV

    Cx < 300 nF

    CVT test

    Cx < 300 nF

    LCR measurement range

    L>20H(2kV)

    R>10KΩ(2kV)

    LCR measurement accuracy

    0.1%

    Angle resolution

    0.01

    CVT ratio range

    10~10000

    CVT ratio accuracy

    0.1%

    CVT ratio resolution

    0.01

    Dimension

    Main unit: 350(L)×270(W)×270(H)

    Accessory box: 350(L)×270(W)×160(H)

    Memory capacity

    200 groups, USB flash disk storage is supported.

    Weight

    Main unit: 22.75Kg

    Accessory box: 5.25Kg

     




    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • русский

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.