    GD-4136H Cable Fault Locating System hits:

    GD-4136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.

     

    The system contains below units:

    1. GD-2131H Impulse Generator

    2. GD-4132 Cable Fault Locator

    3. GD-4133 Multi-pulse Cable Fault Tester

    4. GD-4133S Multi-pulse Coupler

    5.  Other accessories



    GD-2131H Impulse Generator

    It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault.


    Features

           Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased.

           If working together with GD-4133 Cable Fault Tester, there are two locating ways:

      a. Low voltage pulse: If only using GD-4133, open circuit and low impedance grounding faults of cable can be located, and the length of cable can be measured or wave speed of cable can be detected.

      b. High voltage flashover: The discharging pulse voltage waveform of fault point is sampled by discharging sphere gap, which can locate fault distance.

           Generate impulse of fixed frequency. If working together with GD-4132 Cable Fault Locator, there are following functions:

              a. Audio frequency: locate high impedance, flash-over faults.

              b. To pinpoint cable’s route, identify special cable.

              c. To metallic breakdown(dead grounding), using magnetic-field measurement to locate accurately.

     It also can be used in DC HV withstand test.

     

    Specifications

           Input power supply: AC 220V,50Hz

           Output voltage: DC 0-32kV (adjustable)

           Rated power: 2kVA

           Max.energy: 2048J, 4uF

           DC flashover voltage: 32kV

           DC flashover current: 63mA

           Max.impulse current: 500mA

           Discharging method: DC HV, one time, cycle

           Cycle discharging time: 3-6 seconds

           Environmental temperature:0-40℃

           Humidity:<75% RH

           Altitude:<1000m

           Insulation level: A

           Dimension: 430*540*410mm

           Weight:about 31kg.

     

    GD-4132 Cable Fault Locator

    Including main unit, acoustic and magnetic sensor, anti-noise headphone and charger.

    It is suitable to test all kinds of power cable with metallic conductor.

    Its main function is locating poor insulation point, detecting circuit and depth of power cable.

     

    Features

    • Acoustic Magnetic receiving at the same time,
    • Strong anti-interference ability
    • With anti-noise headphone.
    • 320*240 LCD screen display
    • Built-in big capacity Li-battery, with fast charger.
    • Acoustic and Magnetic signal waveform display, signal and noise is easy to distinguish.
    • Using cursor to measure acoustic and magnetic delay, accurately determine fault point.
    • According to initial polarity of magnetic.waveform, it can locate and route detection.


    Specifications

    1. Locating function

    a. Acoustic signal transmission band: center frequency 400Hz, bandwidth 200Hz

    b. Signal gain: 80dB

    c. Locating accuracy: 0.1m

     

    2. Power Supply

    a. Built-in Li-battery, nominal voltage 7.4V, capacity 3000mAH.

    b. Power consumption: 300mA, continuous working time 9hours.

    c. Charger: input AC220V±10%, 50Hz. Nominal output 8.4V, DC 1A

    d. Charging time: 4hours


    3. Dimension: 270mm*150mm*210mm

    4. Weight: 1.5kg.

    5. Use condition

    Temperature -10℃--40℃, humidity 5-90%RH, altitude <4500m


    GD-4133 Cable Fault Detector

    GD-4133 Cable Fault Locator is used to measure distance between cable faults. It’s easy to operate and with friendly interface.

     

    It can be used alone under the low voltage pulse mode. Under the mode of pulse current,it needs to work with GD-2131 high voltage generator. Under the multiple pulse mode, GD-4133S coupler should be worked together. After distance locating, GD-4132 fault locator should be used for fault pinpointing. These products can be combined into

    a set of high performance and innovative cable fault testing system.

     

    Features


    • 7inch LCD screen, friendly interface.
    • Multiple distance locating method:
    • Low voltage pulse method: it is suitable for the locating of the low resistance fault, short circuit fault, open circuit fault. It also can be used in the measurement of the cable length, the intermediate joints, T joints, and cable termination joint. This method also can be used to correct the wave velocity.
    • Pulse current method: It is suitable for distance measurement of the high resistance fault, breakdown fault. Using the current coupler to collect signals from the earth wire, it makes the user far away from the high voltage. This method is safe and reliable.  
    • Multiple pulse: the advanced way to measure distance. The waveform is easy to identify and the accuracy is high.
    • 200MHz real-time sampling. Max. 0.4m measurement resolution. It has small dead zone and is special for the short cable and near fault cable.
    • Touch screen and press key operation
    • PIP copy (pic. temporary storage)
    • There will be a main window and three temporary storage windows could check three waveforms 
    • together.
    • Built-in operating system
    • Special software management for software upgrade, backup and restore.
    • Scale function
    • A starting point,10 contacts, one cable fault and one full length could be setting.
    • Display scale and testing waveform together
    • Waveform storage and communication with computer.
    • Internal storage of waveforms.
    • With USB, to download or upload data
    • Communication with computer
    • Power management
    • Backlight weakens if no operation in 2mins and power off in 10mins if no operation.
    • Built-in Polymer Lithium-ion battery.
    • Working time is up to 5 hours for each use.
    • Strong case, easy to carry.


     

    Specifications

    Locating methods:

    Low voltage impulse method

    Impulse current method

    Multiple impulse method if matched with GD-4133S

    Max. Sampling frequency:

    200MHz

    Gain range:

    0-70dB

    Low voltage impulse voltage:

    30V

    Max.resolution:

    0.4m

    Max. Locating range:

    100km

    Dead zone:

    2m

    Battery:

    Nickel-metal hydride rechargeable batteries,endurance time over 5 hours

    Communication interface:

    USB

    Power supply:

    Input AC220V,50Hz,current 2A,charge for 8 hours

    Dim.:

    274×218×81mm

    Weight:

    3.5kgs

    Operating Temperature:

    -10℃40℃

    Humidity:

    5-90%RH

    Elevation:

    <4500m

     

    GD-4133S Multiple Pulse Coupler

    It is working together with GD-4133 Cable Fault Detector, used for detecting high impedance leak fault, flashover fault, low impedance earth and open circuit fault of power cables. GD-4133S supplied pulse coupling signal for GD-4133 and isolate it from high voltage equipment.

     

    Using the most advanced technology of multiple pulse and pulse balance. The reflected waveform is more easy to identify.

    With safety HV protection, the measuring circuit and high voltage impulse power is electrically isolated.

    Easy wiring, safe and reliable.

     

     

    Specifications

    Pulse voltage: 300V(P-P)

    Allowable input impulse voltage: <35kV

    Allowable input impulse energy: <2000J

    Power input: 220V AC, 50Hz

    Dimension: 560*230*220mm

    Weight: 7kg.



    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • русский

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.