    GDCY Series Impulse Voltage Test System hits:

    Product Description


    GDCY series Impulse Voltage Generator can produce a wide range of voltage and energy to simulate waveform such as lightning impulse, lightning clipped wave, switching impulse and so on, enable to carry out various forms of impulse test for high voltage power equipment, cooperate with steepening device can carry out steep wave test on the insulator (insulator string).



    Features

    • Complete equipment and wide voltage levels in the whole set of device .
    • Small electric inductance in the return circuit of the impulse voltage generator,A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
    • Large in voltage utilization coefficient.
    • Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
    • An automatic control technique is adopted in the constant-current charge,which is high automation and strong anti-interference capacity.
    • A digital measurement and analysis system for the impulse test date are adopted,which increase the technical level and the efficiency of the impulse voltage tests.


    Specifications

    Impulse voltage grade

    100kV-7200kV

    Standard lightning wave

    1.2±30%/50±20%µS

    Peak oscillation

    <5%

    Standard switching wave

    250±20%/2500±60%µS

    Virtual front time of oscillating lightning wave

    15µS

    Virtual front time of oscillating switching wave and 

    virtual front time of oscillating switching impulse wave

    15µS-1mS

    The minimum output voltage

    10%Un

    Charging voltage instability

    <±1%

    Synchronizing range

    20%

    Synchronous discharge error rate

    <2%

    Ignition range

    10%~100%


    Working time

    70%UN Discontinuous work (charge-discharge 300s/time)

    <70%nn Continuous work (charge-discharge 120s/time)

    Generator efficiency: lightning wave (no load)

    90%

    Time to chopping

    2~5µS



    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.