    GDFR-D1 series AC/DC Voltage Meter hits:

    GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.  

     

    Features

    1. Balance type equal potential shield structure.

    2. Fully-sealed insulation cylinder with internal excellent components.

    3. High accuracy and linearity, good stability and anti-interference ability.

    4. With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.

    5. Small size, light weight, easy to carry in the field work.

    6. Inner shield anti-interference system.

    7. The voltage ratio can be customized, suitable for calibration.

    8. External voltage meter can be connected.


    Technical Specifications


    Model No.

    GDFR-D1-50

    GDFR-D1-100

    GDFR-D1-150

    GDFR-D1-200

    GDFR-D1-300

    GDFR-D1-400

    Voltage(kV)

    50

    100

    150

    200

    300

    400

    DC frequency(Hz)

    <2

    AC frequency(Hz)

    30-300

    Accuracy

    (G type)

    AC: 1.0%/DC: 0.5%

    --

    Accuracy

    (H type)

    AC: 0.5%/DC: 0.5%

    --

    --

    Impedance

    ()

    650

    1280

    2000

    2640

    4000

    5360

    Capacitance

    (pF)

    500

    250

    400/160

    300

    200

    300

    Voltage ratio

    1000:1 or 10000:1(or customized)

    Height (mm)

    500

    650

    900

    1200

    1750

    2350

    Dimension

    (mm)

    150×150

    160×160

    200×200

    260×260

    800×800

    Cable impedance(Ω)

    50 / 75

    Range

    1. Low range: 0-20kV

    2. High range: 20kV-rated voltage 

    1. Low range: 0-200kV

    2. High range: 200kV-rated voltage

    Cable length(m)

    3

    4

    5

    6

    8

    10

    Weight(kg)

    5.5

    6.9

    10.6

    14.1

    23.5

    48.2

    Packing Medium

    Imported dry type high polymer materials


    Operation temperature

    0℃-45℃

    Relative humidity

    <85%RH, no condensation

    Altitude

    <1500m(or customized)

    Use condition

    Indoor use or outdoor use in Sunny day


    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • русский

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.