    20kV GDCY-20 Impulse Voltage Generator hits:


    Product Description

    The impulse voltage generator is mainly used to the field of impulse voltage tests by lightning impulse voltage full wave, lightning impulse voltage chipped wave and operate impulse voltage wave for such test products as electrical instrument.


    Features

    • Complete equipment and wide voltage levels in the whole set of device .
    • Small electric inductance in the return circuit of the impulse voltage generator,A band-stop filtering is  adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
    • Large in voltage utilization coefficient.
    • Convenient in wave adjustment, simple in operation, excellent in synchronization  performance and  reliable in motion.
    • An automatic control technique is adopted in the constant-current charge,which is high automation and  strong anti-interference capacity.
    • A digital measurement and analysis system for the impulse test date are adopted,which increase the  technical level and the efficiency of the impulse voltage tests.

    Specifications

    Standard 

    voltage (kV)

    Impulse 

    capacitance (uF)


    Deferred 

    Capacitance(uF)

    Impulse 

    energy(XJ)

    Deferred 
    Voltage (kV)

    Deferred 

    coefficient

    Weight(kg)


    ±1600
    0.0625
    0.5 80 ±200
    8 7353
    0.09375
    0.75 120
    8 7513
    0.125
    1 160 8 8873
    ±1800
    0.0556
    0.5 90 9 7838
    0.0833
    0.75 135 9 8018
    0.1111
    1 180 ±200
    9 9548
    ±2200
    0.0456
    0.5 110 ±200
    11 8810
    0.0682
    0.75 165
    ±200
    11 9030
    0.09091
    1 220 ±200
    11 10900
    ±2400
    0.0417
    0.5 120 ±200
    12 9294
    0.0625
    0.75 180 ±200
    12 9534
    0.0833
    1 240 ±200
    12 11574
    ±2800
    0.0357
    0.5 140 ±200
    14 10266
    0.0536
    0.75 210 ±200
    14 10546
    0.0174
    1 280 ±200
    14 12925
    ±3000
    0.0333
    0.5 150 ±200
    15 10750
    0.05
    0.75 225 ±200
    15 11050
    0.067
    1 300 ±200
    15 13600
    ±3200
    0.03125
    0.5 160 ±200
    16 13760
    0.04687
    0.75 240 ±200
    16 14720
    0.0625
    1 320 ±200
    16 15680
    ±3600
    0.0278
    0.5 180 ±200
    18 15480
    0.04167
    0.75 270 ±200
    18 16560
    0.0556
    1 380 ±200
    18 17640
    ±4000
    0.025
    0.5 200 ±200
    20 17200
    0.0375
    0.75 300 ±200
    20 18400
    0.05
    1 400 ±200
    20 19600
    ±4200
    0.0238
    0.5 210 ±200
    21 18060
    0.0357
    0.75 315 ±200
    21 19320
    0.0476
    1 420 ±200
    21 20580
    ±4800
    0.0208
    0.5 240 ±200
    24 21840
    0.03125
    0.75 380 ±200
    24 22020
    0.0471
    1 480 ±200
    24 23500

    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • русский

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.