Cable Fault Location System

  • GDTG-600A Cable Fault Locator

    GDTG-600A Cable Fault Locator

    GDTG-600A Cable Fault Locator is a portable open-air instrument working on TDR and bridge methods, adopting advanced micro-electronics technology. It is designed to locate accurate fault points in such cables as telecommunication plastic cable or user’s lead covered wire, while the faults include break, mix, earthing, defective insulation, or poor connecting. It is an ideal function-stable instrument for the open-air operator to improve work efficiency; in addition, it can also be used for circuitry project checking electric property testing of the cable. 

     

     

     

     

     

  • HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of Cables

    HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of Cables

    HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of 10KV Cables is an integrated partial discharge location and management system. Partial discharge test with DAC waves,Test frequency varies from 50Hz to hundreds of Hertz under damping AC voltage.

  • GD-4138H Cable Fault Locating System

    GD-4138H Cable Fault Locating System

    The trolley-type cable fault locating system highly integrates traditional and independent cable fault testers, integrated high-frequency and high-voltage power supplies, multiple pulse generators, path transmitters, insulation resistance testers, and other independent units. The system is used for rough testing of various fault distances, path finding, and precise fault location of power cables. The testing software automatically recognizes the card position and reads the fault distance, truly making the testing of cable faults light, simple, efficient, and safe. Provide convenience for rapid testing of power cable faults.

  • GD-4136H Cable Fault Locating System

    GD-4136H Cable Fault Locating System

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. 

     

     

  • GD-2136H Cable Fault Locating System

    GD-2136H Cable Fault Locating System

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.

     

Send your message to us:

Write your message here and send it to us