China High Quality Battery Cell Impedance Tester Manufacturers – GDKH-10 Battery Activator – HV Hipot
China High Quality Battery Cell Impedance Tester Manufacturers – GDKH-10 Battery Activator – HV Hipot Detail:
General Information
In all operating equipment and operating network systems with increasing informationization and automation, uninterrupted power supply is the most basic guarantee. Whether it is AC or DC uninterruptible power supply system, the battery acts as backup power source plays an important role in power source system. Usually, the battery is in the state of floating charge standby. Once the AC power is lost or other accidents, the battery becomes the sole energy supplier of the load.
We know that in addition to the normal life cycle of the battery, some of the early failure of the battery may occur due to problems such as the quality of the battery itself, defects in materials, structures, processes, and improper use. In order to verify the standby time and actual capacity of the battery pack and ensure the normal operation of the system, it is necessary to perform a verification test of the capacity of the battery pack on a regular or as needed basis to detect individual failures at an early stage. Replace the failed single cells to ensure the effectiveness of the entire battery; or to assess the life expectancy of the entire battery.
Features
● Using high-power winding resistance, the discharge current is more stable and fast.
● There is a USB interface, which can transfer the data of the charging and discharging process to the U disk and import it into the PC. PC data management software analyzes the process of battery discharge and generates corresponding data reports. Make data transfer more convenient.
● It adopts intelligent single-chip ARM control and 7-inch touch LCD for Chinese and English display. The menu operation is simple and straightforward.
● The automatic protection function automatically sets the charge and discharge time to, the charge and discharge capacity, the battery voltage is lower than the set minimum protection voltage, the load connection line is abnormal, and automatically stops discharging and alarms, and automatically records the stop mode.
● A variety of charge and discharge termination conditions, including battery termination voltage, discharge capacity, discharge time, to ensure the safety of the discharge test.
● Up to 10 automatic discharge-charge cycles can be set
Specifications
Output voltage |
1.5~16V |
Output current |
2V battery: 0~100A; 4/6V battery: 0 ~60A; 12V battery: 0~30A |
Single cell voltage resolution |
2V: 0.001V; 6V/12V: 0.001V |
Working mode |
Single machine use, constant current mode |
Protection performance |
Over voltage protection: LCD prompt; Over current protection: LCD prompts; 65°C overheat protection: LCD prompt, buzzer alarm; |
Voltage test accuracy |
0.5% |
Current test accuracy |
1% |
Current control accuracy |
0.1A |
Data storage capacity |
2Gbit FLASH |
Heat transfer |
Forced air cooling |
Temperature |
Working range: -5~50°C Storage temperature: -40~70°C |
Humidity |
Relative humidity 0~90% (40±2°C) |
Altitude |
4000 meters |
Noise |
<60dB |
Voltage |
Single-phase three-wire system 220V AC (–20% to +30%), frequency: 45 to 65Hz; |
Withstand voltage test |
Input – Case: 2200Vdc 1min Input-output: 2200Vdc 1min Output – Case:700Vdc 1min |
Safety |
Meet EN610950 |
AC input |
public socket for 1~1.5mm2 cable |
DC output |
25mm2 cable quick connector (red positive black negative) |
Product detail pictures:


Related Product Guide:
It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions continuously. It regards prospects, success as its personal success. Let us build prosperous future hand in hand for China High Quality Battery Cell Impedance Tester Manufacturers – GDKH-10 Battery Activator – HV Hipot , The product will supply to all over the world, such as: Denver, Irish, Iraq, As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products and solutions we supply, effective and satisfying consultation service is supplied by our professional after-sale service group. Solution lists and thorough parameters and any other info weil be sent for you timely for the inquiries. So make sure you get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we have been going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.

We have been looking for a professional and responsible supplier, and now we find it.
