Using a complete scientific high quality management program, superior high quality and superior faith, we acquire great reputation and occupied this industry for Hipot Test, Ipec Partial Discharge, Voltage Coupling, We are sincerely looking forward to cooperate with customers all over the world. We believe we can satisfy with you. We also warmly welcome customers to visit our factory and purchase our products.
China High Quality Capacitor Meter Price Manufacturers – VLF AC Hipot Test Set – HV Hipot Detail:

Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.

Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test.

Aspects

DC

Power Frequency

Variable Frequency

0.1Hz

Equivalency

poor

good

good

good

Insulation Damage

strong

slight

slight

slight

Operation Safety

relatively low

relatively low

relatively low

high

Wiring Difficulty

complicated

complicated

most complicated

simple

Volume

smallest

largest

large

small

In fact VLF test is the substitute for power frequency test. It is suitable for testing electrical equipment with large capacitance (like power cable, power capacitor, motor, and generator).

Description

The new generation of VLF series 0.1Hz VLF AC Hipot Test Set developed by HV Hipot adopts “Smart Quick” intelligent power test system (Soft No. 1010215, trademark registration number 14684781), HV HIPOT company introduced the latest international power electronic components and the latest ARM7 microcontroller technology, further reducing the size and weight of the equipment. The operation is easier, and the performance is more stable.

Features

● Advanced technology adopts digital frequency conversion technology, fully automatic microcomputer control, voltage boost, step-down, measurement, protection, etc.
● Control part and High-voltage part adopt an integrated structure design, and only a high voltage wire and ground wire are needed to connect to the tested product without the intermediate connection wire.
● Trolley-style design is convenient for transportation in various working environments, and its small size and light weight are very conducive to outdoor operations(80kV).
● Over-voltage protection and over-current protection. Action time is no longer than 10ms.
● The control unit and the booster are connected at low voltage, with photoelectric isolation control, safe and reliable to use.
● Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
● Capacitive touch screen, LCD graphic display, automatic storage, and printing.
● 0.1Hz, 0.05Hz and 0.02Hz can be chosen, which ensures a wide test range.

Specifications

● Peak voltage: 30kV
● Test frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
● Maximum load capacity: 1.1μF@0.1Hz   /   2.2μF@0.05Hz   /   5.5μF@0.02Hz
● Measurement accuracy: 3%.
● Voltage peak value error: ≤3%.
● Voltage waveform distortion: ≤5%.
● Working environment: indoor or outdoor; -10℃-+40℃; 85%RH
● Fuse: 8A (30kV)
● Power supply: 220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW, frequency 50Hz, voltage 220V±5%.)
● Capacitance of the tested object shall not exceed the max. rated capacitance of the instrument.


Product detail pictures:

China High Quality Capacitor Meter Price Manufacturers –  VLF AC Hipot Test Set – HV Hipot detail pictures

China High Quality Capacitor Meter Price Manufacturers –  VLF AC Hipot Test Set – HV Hipot detail pictures

China High Quality Capacitor Meter Price Manufacturers –  VLF AC Hipot Test Set – HV Hipot detail pictures

China High Quality Capacitor Meter Price Manufacturers –  VLF AC Hipot Test Set – HV Hipot detail pictures


Related Product Guide:

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for China High Quality Capacitor Meter Price Manufacturers – VLF AC Hipot Test Set – HV Hipot , The product will supply to all over the world, such as: Kenya, Albania, Dominica, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Josephine from Swaziland - 2018.05.15 10:52
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Sahid Ruvalcaba from Rio de Janeiro - 2017.06.19 13:51

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us