China High Quality Capacitor Tan Delta Manufacturer – High voltage divider GDFR-D1 – HV Hipot
China High Quality Capacitor Tan Delta Manufacturer – High voltage divider GDFR-D1 – HV Hipot Detail:
GDFR-D1 series AC/DC Voltage Meter
GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.
Technical Specifications
Model No. | GDFR-D1-50 | GDFR-D1-100 | GDFR-D1-150 | GDFR-D1-200 | GDFR-D1-300 | GDFR-D1-400 | |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 | |
DC frequency(Hz) | <2 | ||||||
AC frequency(Hz) | 30-300 | ||||||
Accuracy (G type) |
AC: 1.0%/DC: 0.5% | – | |||||
Accuracy (H type) |
AC: 0.5%/DC: 0.5% | – | – | ||||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 | |
Capacitance (pF) |
500 | 250 | 400/160 | 300 | 200 | 300 | |
Voltage ratio | 1000:1 or 10000:1(or customized) | ||||||
Height (mm) | 500 | 650 | 900 | 1200 | 1750 | 2350 | |
Dimension (mm) |
150×150 | 160×160 | 200×200 | 260×260 | 800×800 | ||
Cable impedance(Ω) | 50 / 75 | ||||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage |
1. Low range: 0-200kV 2. High range: 200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 5 | 6 | 8 | 10 | |
Weight(kg) | 5.5 | 6.9 | 10.6 | 14.1 | 23.5 | 48.2 | |
Packing Medium | Imported dry type high polymer materials | ||||||
Operation temperature | 0℃-45℃ | ||||||
Relative humidity | <85%RH, no condensation | ||||||
Altitude | <1500m(or customized) | ||||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:
Related Product Guide:
We've been committed to offering easy,time-saving and money-saving one-stop purchasing service of consumer for China High Quality Capacitor Tan Delta Manufacturer – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Mombasa, Belarus, Portugal, We care about every steps of our services, from factory selection, product development & design, price negotiation, inspection, shipping to aftermarket. We have implemented a strict and complete quality control system, which ensures that each product can meet quality requirements of customers. Besides, all of our products have been strictly inspected before shipment. Your Success, Our Glory: Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us.
By Elma from Hanover - 2017.03.07 13:42
As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
By Katherine from The Swiss - 2017.08.21 14:13