China High Quality clamp meter tester Factories – GDHX-9700 Phase Detector – HV Hipot
China High Quality clamp meter tester Factories – GDHX-9700 Phase Detector – HV Hipot Detail:
General Information
GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.
The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10V-500KV). When checking the grid structure, it can accurately identify the relative phase of different leads for the three-phase connected line, without any electrical connection between two measurement components, which makes the application of the measurement device very flexible and safe.
Features
● Voltage range: 10V~500KV, applicable for various voltage grades.
● Accuracy: short distance: error ≤±3°; long distance: error ≤±3°.
● Sampling rate: 10 times/second.
● Date and time setting, date and time adjustment, easy for users to browse, view the historical data.
● Backlight setting: normally on, normally off, user-defined within 0~999s.
● Auto shut-down: never, user-defined within 0~999 minutes.
● In-phase: ≤20° (user-defined if phase threshold is within 0-90°, default 20°)
● Out-phase: >20° (user-defined if phase threshold is within 0-90°, default 20°)
● On-site calibration function: on-site calibration can be carried out on the tested wire to ensure the accuracy of phase angle.
● Multiple mode design, better applicability, more secure, more convenient.
● Unique human-machine interface, simple operation.
● FCC antenna design, stronger signal, easier to penetrate walls, doors, and barriers.
● Double shielding, strong anti-interference, in full compliance with EMC standards.
● Charts and data display, easier to read, with date and time display function.
● Qualitative measurement: display by acousto-optic signal.
● Quantitative measurement: real-time display of phase angle difference, error ≤5°.
● Phase sequence check: positive phase sequence, negative phase sequence (120°, 240°).
● Under GPS satellite timing service, the detection distance between detector Xa and Ya is ≥500km.
● Data storage capacity of 2000 groups. It can query and access to historical data.
● The length of standard insulation rod is 4m, and the applicable voltage grade of insulation rod is ≤ 220kV.
Technical Parameters
Voltage range |
10V~500kV |
Power supply |
Hand-held unit: large capacity lithium battery |
Xa & Ya detector: AA size alkaline battery (1.5V) 3pcs |
|
Wireless transmission |
Visual distance 150m |
In-phase |
≤20° (user-defined if phase threshold is within 0-90°) |
Out-phase |
>20° (user-defined if phase threshold is within 0-90°) |
Display accuracy |
Quantitative measurement ≤5° |
Resolution of phase angle |
1° |
Phase sequence measurement |
Phase sequence is determined through clockwise 120°/ counterclockwise 240° |
Satellite timing range |
2~30 minutes |
Display |
Positive type LCD screen, clear in the sunlight. |
Working temperature |
-35~+50℃ |
Storage temperature |
-40~+55℃ |
Relative humidity |
≤95%RH, condensing |
Hand-held unit |
0.31 kg |
Detector Xa |
0.16 kg |
Detector Ya |
0.16 kg |
Product detail pictures:



Related Product Guide:
To create much more benefit for consumers is our company philosophy; customer growing is our working chase for China High Quality clamp meter tester Factories – GDHX-9700 Phase Detector – HV Hipot , The product will supply to all over the world, such as: Indonesia, Macedonia, Belgium, Due to the stability of our items, timely supply and our sincere service, we are able to sell our merchandise not only over the domestic market, but also exported to countries and regions, including the Middle East, Asia, Europe and other countries and regions. At the same time, we also undertake OEM and ODM orders. We will do our best to serve your company, and establish a successful and friendly cooperation with you.

High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
