China High Quality Couple Capacitor Factory – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot
China High Quality Couple Capacitor Factory – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot Detail:
Application
AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.
Features
● Pointer display panel mounted controls & indicators with easy-to-read legend.
● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing.
● Over-current protection, zero-starting protection, sound, and light alarm.
● Continuously variable output from zero to full voltage.
● Adjustable over current protection, with trip levels variable from 10 to 110%.
● With new type time relay, time range is wider (1S ~ 99H).
● Using the latest current relay, more accurate and reliable.
● Light weight, small size, easy to move.
Technical Specifications
● Input voltage: AC 220V or 380V
● Output voltage of control unit: AC 0-250V or 0-430V
● Output current of control unit:0-5/10/15/50A(customized)
● Capacity: 0-3/5/10/15/20/30/50/100kVA(customized)
● Output voltage of HV unit: 0-50/100/150/200kV(customized)
● Output current of HV unit: 0-50/100/150/200/500/1000/2000mA(customized)
● Timing: 0-9999s
● Environmental temperature: -20℃–50℃
● Voltage accuracy: ≤ 1.5%±1digit (F.S)
● Current accuracy: ≤ 1.5%±1digit (F.S)
Other accessories for option
● AC Digital Voltage Meter: 50,100,150, 200kV
● Sphere Gap
● Discharge stick
● Water resistor or solid protective resistor
● HV filter capacitor: 0.01μF-0.1μF, 40-300kV
We can customize different ratings based on different requirement. Welcome to consult with us!
Product detail pictures:





Related Product Guide:
We're going to dedicate ourselves to offering our esteemed shoppers with the most enthusiastically considerate solutions for China High Quality Couple Capacitor Factory – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot , The product will supply to all over the world, such as: Provence, Manchester, Bogota, we rely on own advantages to build a mutual-benefit commerce mechanism with our cooperative partners. As a result, we have gained a global sales network reaching the Middle East, Turkey, Malaysia and Vietnamese.

Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
