China High Quality Dc Tester Exporters – High voltage divider GDFR-D1 – HV Hipot
China High Quality Dc Tester Exporters – High voltage divider GDFR-D1 – HV Hipot Detail:
GDFR-D1 series AC/DC Voltage Meter
GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.
Technical Specifications
Model No. | GDFR-D1-50 | GDFR-D1-100 | GDFR-D1-150 | GDFR-D1-200 | GDFR-D1-300 | GDFR-D1-400 | |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 | |
DC frequency(Hz) | <2 | ||||||
AC frequency(Hz) | 30-300 | ||||||
Accuracy (G type) |
AC: 1.0%/DC: 0.5% | – | |||||
Accuracy (H type) |
AC: 0.5%/DC: 0.5% | – | – | ||||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 | |
Capacitance (pF) |
500 | 250 | 400/160 | 300 | 200 | 300 | |
Voltage ratio | 1000:1 or 10000:1(or customized) | ||||||
Height (mm) | 500 | 650 | 900 | 1200 | 1750 | 2350 | |
Dimension (mm) |
150×150 | 160×160 | 200×200 | 260×260 | 800×800 | ||
Cable impedance(Ω) | 50 / 75 | ||||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage |
1. Low range: 0-200kV 2. High range: 200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 5 | 6 | 8 | 10 | |
Weight(kg) | 5.5 | 6.9 | 10.6 | 14.1 | 23.5 | 48.2 | |
Packing Medium | Imported dry type high polymer materials | ||||||
Operation temperature | 0℃-45℃ | ||||||
Relative humidity | <85%RH, no condensation | ||||||
Altitude | <1500m(or customized) | ||||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:

Related Product Guide:
We consistently carry out our spirit of ''Innovation bringing development, Highly-quality ensuring subsistence, Management promoting benefit, Credit attracting customers for China High Quality Dc Tester Exporters – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Guatemala, Sao Paulo, Liverpool, Our technical expertise, customer-friendly service, and specialized products make us/company name the first choice of customers and vendors. We are looking for your inquiry. Let's set up the cooperation right now!

This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
