China High Quality determine dew point Exporters – GDND-800 Freezing Point Tester – HV Hipot

China High Quality determine dew point Exporters – GDND-800 Freezing Point Tester – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We insist about the theory of growth of 'High excellent, Performance, Sincerity and Down-to-earth working approach' to offer you with great company of processing for Transformer Oil Dielectric Loss, Dc Hipot, Pd Sensor, We are looking forward to cooperating with all customers from at home and abroad. Moreover, customer satisfaction is our eternal pursuit.
China High Quality determine dew point Exporters – GDND-800 Freezing Point Tester – HV Hipot Detail:

General Information 

1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.
2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products.

Working conditions

1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment.
2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during operation.
3. When the instrument is not in use, it should be placed in a dry and ventilated place.
4. The power supply is single-phase three-wire system and must have a good grounding terminal.
5. The environmental conditions for the instrument use are: ambient temperature 5~30℃, humidity ≤85%, working power supply AC220V±10%, 50Hz.

Specification

Refrigerant R13 R502
Cooling time ≤100min (ambient temperature ≤30℃)
Stop interval >30min
Stirring motor power 22W * 2
Stirring motor allows temperature rise 80℃
Power 800W
Voltage 220V±10%, 50Hz±1Hz
Temperature control range room temperature ~ -70℃
Temperature control accuracy ±0.5℃
Temperature display LED
Temperature sensor Pt100
Timer LED

Product detail pictures:

China High Quality determine dew point Exporters –  GDND-800 Freezing Point Tester – HV Hipot detail pictures


Related Product Guide:

We generally continually give you quite possibly the most conscientious shopper company, and the widest variety of designs and styles with finest materials. These endeavours include the availability of customized designs with speed and dispatch for China High Quality determine dew point Exporters – GDND-800 Freezing Point Tester – HV Hipot , The product will supply to all over the world, such as: Cyprus, Finland, Ukraine, We warmly welcome domestic and overseas customers to visit our company and have business talk. Our company always insists on the principle of "good quality, reasonable price, the first-class service". We are willing to build long-term, friendly and mutually beneficial cooperation with you.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Sharon from Senegal - 2018.06.26 19:27
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Gemma from Malta - 2018.08.12 12:27

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us