China High Quality Dew point meters Supplier – GDKS-205 Automatic Flash Point Open Cup Tester – HV Hipot
China High Quality Dew point meters Supplier – GDKS-205 Automatic Flash Point Open Cup Tester – HV Hipot Detail:
General Information
GDKS-205 automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department.
Features
● 320*240 TFT LCD touch screen.
● With high speed signal processor control, reliable and high accuracy.
● One host can control several test furnace to test several samples at one time, which will save testing time.
● Detection, ignition, alarm, cooling, printing, the whole testing process is completed automatically.
● Platinum electric wire or gas ignition.
● Built-in atmosphere pressure sensor, auto-measure and calibrate result.
● Self-adaptive PID control calculation, automatic adjusting temperature rise curve according to standard requirements.
● With fault auto-detection alarm function.When sensor fault, sample mistake, temperature over value, the instrument will stop automatically and alarm.
● Calendar clock with temperature compensation, and accurate travel time, automatically recording the date and time of measurement, in a power down state can be operation for more than 10 years.
● Built-in high speed thermal printer.
● Store up to 255pcs history records.
● Built in multiple execution criteria for selection.
Specifications
● Temperature measure range: -59.9℃–399.9℃;
● Temperature control range: room temperature–399.9℃;
● Repeatability: ≤150℃ 3℃; >150℃ 5℃;
● Resolution: 0.1℃;
● Accuracy: 0.5%;
● Thermometric sensor: Pt resistance (PT100);
● Flash fire sensor: Ion detection ring;
● Power voltage: AC220V±20% 50HZ±10%;
● Max.Power: <500W;
● Environmental temperature: -10℃-40℃;
● Relative humidity: ≤85% RH;
● Ignition method: Gas flame or electric ignition;
● Weight: 14kg;
● Dimension: 440*280*290mm;
Product detail pictures:

Related Product Guide:
With dependable high-quality method, fantastic standing and ideal purchaser assistance, the series of products produced by our firm are exported to many countries and regions for China High Quality Dew point meters Supplier – GDKS-205 Automatic Flash Point Open Cup Tester – HV Hipot , The product will supply to all over the world, such as: Jordan, Malaysia, Puerto Rico, Due to the stability of our products, timely supply and our sincere service, we are able to sell our products not only over the domestic market, but also exported to countries and regions, including the Middle East, Asia, Europe and other countries and regions. At the same time, we also undertake OEM and ODM orders. We will do our best to serve your company, and establish a successful and friendly cooperation with you.

The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
