China High Quality dew point test set manyfacturers Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
China High Quality dew point test set manyfacturers Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.
GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.
Features
● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.
Specification
Measuring range | 0-200mN/m |
Accuracy | 0.1% of the reading±0.1 mN/m |
Resolution | 0.1mN/m |
Sensitivity | 0.1mN/m |
Power supply | AC220V±20%,50Hz±10% |
Maximum power consumption | 20W |
Environmental temperature | 10~30℃(25℃ is the best) |
Environmental humidity | ≤85% RH |
Dimension | 200×300×330(mm) |
Weight | 6kg |
Product detail pictures:


Related Product Guide:
Our concentrate on should be to consolidate and enhance the quality and service of present products, meanwhile consistently produce new products to meet unique customers' demands for China High Quality dew point test set manyfacturers Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Germany, South Africa, Russia, "Make the women more attractive "is our sales philosophy. "Being customers' trusted and preferred brand supplier" is the goal of our company. We are strict with every part of our work. We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.

The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
