Our organization sticks to your principle of "Quality may be the life of your organization, and reputation will be the soul of it" for Impulse Generator, High-Voltage Impulse Test, Power And Distribution Transformer, With a wide range, top quality, reasonable rates and stylish designs, our products are extensively used with this industries and other industries.
China High Quality Digital Microhmmeter Factories – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot Detail:

Adoption of Standard

● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment”
● GB1094.1-GB1094.6-96 “Shell protection level”
● GB2900 “Electrical Terminology”
● GB/T16927.1~2-1997 “High Voltage Test Technology”
● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments”
● GB191 “Package Storage and Transportation Mark”
● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment”

Features

● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong.
● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant.
● The all-metal spray plastic case and the internationally popular camel gray tone are solid and reliable, ensuring the reliability of logistics.
● The use of brake universal casters makes movement and fixing more flexible and convenient.
● Wedge-shaped airflow duct to improve heat dissipation and greatly extend service life.
● The whole machine is small in size and light in weight, which is very suitable for field use.

Functions

● It has zero protection function to prevent the impact of large current from causing damage to the sample. It cannot be started when it is not at zero position.
● Impact selection function, when the circuit breaker quick-break test is performed, the zero protection function can be cut off and the required current value can be directly output.
● Output current mode: The true RMS value is continuously adjustable.
● The output current is a standard sine wave, and the waveform distortion rate is less than 5%.
● Voltage and current display adopts new high-precision LED digital display
● Switchable size current range to improve display fineness for more accurate readings.
● The power supply voltage and regulator output voltage can be switched to display for easy viewing.
● The equipment capacity is designed for short-term, intermittent work in 5 minutes.
● For batch testing, close for 10 minutes after 2.5 minutes of continuous operation.
● It can measure the current action time of the tested component and record the lock action time synchronously. (optional)
● Measured time range: 0.001S~999.999S Resolution 1ms, measurement error: 0.005% range ± 2digs. (optional)
● The test value of primary current and secondary current can be directly displayed to facilitate the transformer ratio test. (optional)
● Secondary current range 0~5A resolution 1mA (optional)
● If the temperature rise (30 minutes – 24 hours) should be customized according to the long-term work temperature rise. (optional)
● Can be customized three-phase with balance adjustment riser (optional)
● Can be customized AC and DC riser (optional)

Specifications

Model Output capacity (kVA) Output current (A) Power Supply (V) Open circuit voltage (V) Power phase Mark
GDSL-D-500 3 500 220 6 LN Integrated
GDSL-D-1000 6 1000 220 6 LN Integrated
GDSL-D-1500 9 1500 220 6 LN Integrated
GDSL-D-2000 12 2000 220 or 380 6 LN AB Integrated or combination
GDSL-D-2500 15 2500 220 or 380 6 LN AB Integrated or combination
GDSL-D-3000 18 3000 220 or 380 6 AB Integrated or combination
GDSL-D-4000 24 4000 380 6 AB combination
GDSL-D-5000 30 5000 380 6 AB combination
GDSL-D-6000 36 6000 380 6 AB combination
GDSL-D-8000 48 8000 380 6 AB combination
GDSL-D-10000 60 10000 380 6 AB combination
GDSL-D-12000 72 12000 380 6 AB combination
GDSL-D-15000 90 15000 380 6 AB combination
Can be customized due to customer;s special requirements

Accessories

Primary current injection test set 1 piece
Power cord 1 piece
Grounding Wire 1 piece
High Current line(standard 2m) 2 piece
Certificate 1 copy
Manual 1 copy
Packing list 1 copy
Test Report 1 copy

Product detail pictures:

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Digital Microhmmeter Factories –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot detail pictures


Related Product Guide:

Our business promises all users of the first-class items and the most satisfying post-sale company. We warmly welcome our regular and new prospects to join us for China High Quality Digital Microhmmeter Factories – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot , The product will supply to all over the world, such as: Albania, Lebanon, Melbourne, Our company will continue to adhere to the " superior quality, reputable, the user first " principle wholeheartedly. We warmly welcome friends from all walks of life to visit and give guidance, work together and create a brilliant future!
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Afra from Mexico - 2018.12.25 12:43
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Ada from Bangladesh - 2018.11.22 12:28

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us