Our primary intention should be to offer our clientele a serious and responsible enterprise relationship, delivering personalized attention to all of them for Transformer Frequency, Dc Tester, Insulating Oil Testing, All merchandise are manufactured with advanced equipment and strict QC procedures in purchase to assure high-quality. Welcome prospects new and old to get hold of us for enterprise cooperation.
China High Quality flash point in closed cup test Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:

Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.

GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.

Features

● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.

Specification

Measuring range 0-200mN/m
Accuracy 0.1% of the reading±0.1 mN/m
Resolution 0.1mN/m
Sensitivity 0.1mN/m
Power supply AC220V±20%,50Hz±10%
Maximum power consumption 20W
Environmental temperature 10~30℃(25℃ is the best)
Environmental humidity ≤85% RH
Dimension 200×300×330(mm)
Weight 6kg

Product detail pictures:

China High Quality flash point in closed cup test Manufacturer –  GDZL-503 Automatic Interfacial Tension tester – HV Hipot detail pictures

China High Quality flash point in closed cup test Manufacturer –  GDZL-503 Automatic Interfacial Tension tester – HV Hipot detail pictures


Related Product Guide:

By using a full scientific excellent administration method, great quality and fantastic religion, we get good reputation and occupied this discipline for China High Quality flash point in closed cup test Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Peru, Naples, Ghana, With the first-class solutions, excellent service, fast delivery and the best price, we've won highly praise foreign customers'. Our products have been exported to Africa, the Middle East, Southeast Asia and other regions.
  • In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By David from Philadelphia - 2017.09.30 16:36
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Eden from Mauritania - 2018.09.12 17:18

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us