China High Quality Gas Leak Detector Usa Factories – GDWS-311RC SF6 Gas Dew Point Tester – HV Hipot
China High Quality Gas Leak Detector Usa Factories – GDWS-311RC SF6 Gas Dew Point Tester – HV Hipot Detail:
General Information
GDWS-311RC is ideal instrument to test dew point of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument.
Application
● Moisture monitoring of SF6 gas electrical equipment for electric power
● SF6 gas cylinder gas quality test
● High purity gas manufacturing
● Semiconductor industry dry gas supply
● Research and development use
● Clean room/dry house monitoring
● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases.
Features
● Better than ±2℃ measurement accuracy.
● All gas path are polymer material design, ensures no water wall hanging phenomenon and guarantees the test speed.
● The oil-free stainless steel body regulating valve is used to ensure the accuracy of the measured value.
● Advanced software algorithms improve the test accuracy of sensors.
● Combined chassis configuration solution, users can easily combine related instruments and accessories. The overall package is carried, which makes the user have a more relaxed experience.
● Start up test, no need to preheat and oscillate.
● Temperature conversion and pressure data correction.
● Fuzzy computing technology.
● High-power lithium battery power, realize AC and DC dual power supply. No on-site AC power is required. Lithium battery power supply continues to work for more than 8 hours without the need of an external power supply.
● Anti-electromagnetic interference circuit design to ensure product reliability.
● Gas recycling function, environment-friendly.
● The test data is stable and can provide both standard dew point values and converted dew point values at 20℃.
● The best test flow area shows that the user can adjust the gas flow intuitively and quickly. Reduce test time.
● The air inlet is designed with a miniature self-sealing joint, and the air path to be tested will not leak when the air path is disconnected.
Specification
● Measurement method: Resistive and Capacitive measurement principle
● Measurement range: dew point -80℃–+20℃(support ppmv)
● Accuracy: ±2℃
(when the dew point temperature is below 0℃, the sensor output is the frost point)
● Response time: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
● Resolution: 0.01℃
● Repeat-ability: ± 0.5℃
● Display unit: ℃, ppm, ℃P20(converted value at 20℃)
● Gas flow: 400-600ml/min
● Flow display: 0-1000mL digital flow meter
● Sample gas pressure: ≤1MPa
● Power supply: 220VAC±10%, 50Hz, AC/DC use, continuous working is not less than 8 hours.
● Use environment temperature: -20–+60℃
● Environment humidity: 90%RH
● Measurement value influence: No affect of pressure and flow
● Dimension: 395*295*155mm
● Weight: about 2kg
Accessories
Main unit | 1 piece |
Adapter | 1 set |
Teflon pipe(include flow adjustment valve and fast connector) | 1 set |
Tail pipe | 1 set |
Spare parts | 1 set |
Charger | 1 piece |
User’s Guide | 1 copy |
Test Report | 1 copy |
Product detail pictures:



Related Product Guide:
We strive for excellence, services the customers", hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for China High Quality Gas Leak Detector Usa Factories – GDWS-311RC SF6 Gas Dew Point Tester – HV Hipot , The product will supply to all over the world, such as: Armenia, Uzbekistan, Armenia, By continuous innovation, we will present you with more valuable items and services, and also make a contribution for the development of the automobile industry at home and abroad. Both domestic and foreign merchants are strongly welcomed to join us to grow together.

Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
