We always continually offer you the most conscientious purchaser services, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Automatic Dielectric Loss Tester Tan Delta Tester Megger, Distribution Transformers, Partial Discharge Equipment, In a word, when you choose us, you choose a ideal life. Welcome to go to our manufacturing unit and welcome your get! For further more inquiries, remember to usually do not be reluctant to get in touch with us.
China High Quality Gas Sniffer Suppliers – GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot Detail:

General Information

GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission,  SF6 gas electrical switch manufacturing plant and other departments. It can perform to pump vacuum and fill gas for electric equipment.

Features

● Can be moved as a tanker with an armored hose
● Pointer type vacuum display.
● Weighing function. (optional)
● Storage tank heating function. (optional)
● Multi protection-function can ensure safe operation.
● Easy maintenance and high performance.
● Suitable for 10-35kV electrical devices.

Technical Specifications

Vacuum  Pump Rate(L/s)

Limited Vacuum (pa)

Time of pumping vacuum (s)

30L

60L

180L

300L

600L

1200L

4

≤6*10-2

8

16

48

80

160

320

● Dimension: 470mm×670mm×1500mm
● Weight: About 10Kg
● Power Supply: 220-240 V / 50/60 Hz

Basic Components

● 16m3/h vacuum pump H280i
● SF6 pressure reducer (0-1.6MPa)
● Armored hose DN8 / 7 m
● SF6 cylinder connection W 21.8 x 1/14”
● High pressure hose DN8 / 6 m
● DILO connector DN8
● DILO connector DN20


Product detail pictures:

China High Quality Gas Sniffer Suppliers –  GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot detail pictures

China High Quality Gas Sniffer Suppliers –  GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot detail pictures

China High Quality Gas Sniffer Suppliers –  GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot detail pictures

China High Quality Gas Sniffer Suppliers –  GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot detail pictures


Related Product Guide:

In the past few years, our company absorbed and digested advanced technologies both at home and abroad. Meanwhile, our company staffs a team of experts devoted to the development of China High Quality Gas Sniffer Suppliers – GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot , The product will supply to all over the world, such as: Cyprus, Muscat, Bogota, Our products are widely sold to Europe, USA, Russia, UK, France, Australia, Middle East, South America, Africa, and Southeast Asia, etc. Our products are highly recognized by our customers from all around the world. And our company is committed to continually improving effectiveness of our management system to maximize customer satisfaction. We sincerely hope to make progress with our customers and create a win-win future together. Welcome to join us for business!
  • This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Gwendolyn from Liverpool - 2017.03.28 12:22
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Irene from France - 2017.03.28 12:22

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us