Our goal is to satisfy our customers by offering golden service, good price and high quality for Capacitance And Tan Delta Test Set China, Bushing Power Factor Test, Discharge Ac Capacitor With Multimeter, If you have the requirement for any of our products, please contact us now. We are looking forward to hearing from you soon.
China High Quality Hipot Test Voltage Manufacturer – Surge Generator for motor – HV Hipot Detail:

GDZJ-5S Turn to Turn Surge Withstand Tester

GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment.

It can detect below faults:
● Turn-to-turn Insulation breakdown
● Corona discharge
● Winding connection mistake
● Winding disconnection
● Turn-to-turn difference
● Short-circuit between interphase, winding phase, or iron core

Specifications

● Peak voltage: 500-5000V continuous adjustment
● Peak error: ≤ 5% (1kV-5kV)
● Waveform rising time: 0.5μS or 0.2μS
● Power supply: 220V±10%, 50HZ
● Power consumption: ≤ 100 W
● Dimension: 480*260*390mm
● Weight: about 24kg


Product detail pictures:

China High Quality Hipot Test Voltage Manufacturer –  Surge Generator  for motor – HV Hipot detail pictures

China High Quality Hipot Test Voltage Manufacturer –  Surge Generator  for motor – HV Hipot detail pictures

China High Quality Hipot Test Voltage Manufacturer –  Surge Generator  for motor – HV Hipot detail pictures

China High Quality Hipot Test Voltage Manufacturer –  Surge Generator  for motor – HV Hipot detail pictures


Related Product Guide:

owing to fantastic assistance, a variety of high quality goods, aggressive rates and efficient delivery, we love a very good popularity among our customers. We are an energetic firm with wide market for China High Quality Hipot Test Voltage Manufacturer – Surge Generator for motor – HV Hipot , The product will supply to all over the world, such as: America, Ecuador, Miami, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Jane from Netherlands - 2017.03.07 13:42
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Janet from Hyderabad - 2018.12.28 15:18

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us