China High Quality Hv Hipot Supplier – High voltage divider GDFR-D1 – HV Hipot
China High Quality Hv Hipot Supplier – High voltage divider GDFR-D1 – HV Hipot Detail:
GDFR-D1 series AC/DC Voltage Meter
GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.
Technical Specifications
Model No. | GDFR-D1-50 | GDFR-D1-100 | GDFR-D1-150 | GDFR-D1-200 | GDFR-D1-300 | GDFR-D1-400 | |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 | |
DC frequency(Hz) | <2 | ||||||
AC frequency(Hz) | 30-300 | ||||||
Accuracy (G type) |
AC: 1.0%/DC: 0.5% | – | |||||
Accuracy (H type) |
AC: 0.5%/DC: 0.5% | – | – | ||||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 | |
Capacitance (pF) |
500 | 250 | 400/160 | 300 | 200 | 300 | |
Voltage ratio | 1000:1 or 10000:1(or customized) | ||||||
Height (mm) | 500 | 650 | 900 | 1200 | 1750 | 2350 | |
Dimension (mm) |
150×150 | 160×160 | 200×200 | 260×260 | 800×800 | ||
Cable impedance(Ω) | 50 / 75 | ||||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage |
1. Low range: 0-200kV 2. High range: 200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 5 | 6 | 8 | 10 | |
Weight(kg) | 5.5 | 6.9 | 10.6 | 14.1 | 23.5 | 48.2 | |
Packing Medium | Imported dry type high polymer materials | ||||||
Operation temperature | 0℃-45℃ | ||||||
Relative humidity | <85%RH, no condensation | ||||||
Altitude | <1500m(or customized) | ||||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:

Related Product Guide:
We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of China High Quality Hv Hipot Supplier – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Malta, Portugal, azerbaijan, Meanwhile, we're building up and consummating triangle market & strategic cooperation in order to achieve a multi-win trade supply chain to expand our market vertically and horizontally for a brighter prospects. development. Our philosophy is to create cost-effective products and solutions, promote perfect services, cooperate for long-term and mutual benefits, firm a in depth mode of excellent suppliers system and marketing agents, brand strategic cooperation sales system.

We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
