China High Quality Infrared Leak Detector Manufacturers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

China High Quality Infrared Leak Detector Manufacturers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our advancement depends over the highly developed devices, excellent talents and continually strengthened technology forces for The Capacitors, Capacitor 1, Capacitance In Electricity, All products and solutions arrive with high quality and fantastic after-sales expert services. Market-oriented and customer-oriented are what we now have been being immediately after. Sincerely look ahead to Win-Win cooperation !
China High Quality Infrared Leak Detector Manufacturers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot Detail:

Product Description

GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system.

Features

● Automatically calibrate density relay and pressure gauge.
● Compact design, small size, and light weight, easy to carry.
● Color LCD screen, Windows menu.
● The power supply has UPS function, suitable for field operation.
● With mini-printer, to print test result directly.
● Good sealing property, do not waste SF6 gas during calibration.
● The two ends of connection pipe has fast check valve, easy operation and avoid water and air entering into the pipe. No need to dismantle most of density relay to calibrate directly.
● There is automatic voltage protector for sampling point. If sampling point clip misconnecting with 220V voltage, it will not destroy device.  

Functions

Automatically measure pressure when SF6 gas density relay alarm or disalarm at any environmental temperature. It also can convert it to standard pressure at 20℃, to realize alarm performance calibration.

Automatically measure pressure when SF6 gas density relay interlock or relive interlock at any environmental temperature. It also can convert it to standard pressure at 20℃, to realize interlock performance calibration.

If there is pressure gauge or density meter of tested SF6 gas density relay, it can calibrate the accuracy of pressure gauge or density meter.

Convert the SF6 gas pressure into standard pressure at 20℃.

Convert the standard pressure at 20℃ into pressure at any temperature.

Set multiple measurement for one density relay. The measurement result is average value.

Specifications

Power supply: AC/DC use, built-in rechargeable battery, AC 220V±10%, 50Hz
Accuracy: Class 0.25
Display: 3.5inch true color LCD screen
Printer: Needle type microprinter
Measurement pressure range: 0-1.0Mpa
Calibration pressure range: standard pressure 0-0.9Mpa at 20℃
Temperature range: -50℃–100℃
Dimension: 258*240*88mm
Weight: about 2.5kg
Pressure resolution: 0.0001Mpa
Temperature resolution: 0.1℃
Storage capacity: 50-100pcs
Communication port: USB2.0


Product detail pictures:

China High Quality Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot detail pictures

China High Quality Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot detail pictures

China High Quality Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot detail pictures

China High Quality Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot detail pictures

China High Quality Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot detail pictures

China High Quality Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot detail pictures


Related Product Guide:

High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for China High Quality Infrared Leak Detector Manufacturers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot , The product will supply to all over the world, such as: Sevilla, Hungary, Suriname, To have much more enterprise. ompanions, we've got updated the item list and seek for optimistic co-operation. Our web-site shows the latest and complete information and facts about our merchandise list and company. For further acknowledge, our consultant service group in Bulgaria will reply to all of the inquiries and complications immediately. They're about to make their finest effort to meet buyers need. Also we support the delivery of absolutely free samples. Business visits to our business in Bulgaria and factory are generally welcome for a win-win negotiation. Hope to expertise a happy company co-operation perform with you.
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Ellen from Azerbaijan - 2017.11.29 11:09
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Colin Hazel from Puerto Rico - 2017.04.18 16:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us