China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot Detail:
General Information
GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply can be obtained. There are four strong magnets on the back of the instrument, which can be attached to the distribution box for use.
GDCR1000C, GDCR1000D non-contact phase tester has the functions of looping inspection, simple power inspection, circuit breaking search, breakpoint location, line maintenance and so on.
GDCR1000C, GDCR1000D non-contact phase detector detection is fast, convenient and easy to display at a glance, greatly improving the safety of field testing, effectively protecting the personal safety of operators, and increasing productivity! It is a safety instrument for three-phase power supply phase sequence, motor detection and line maintenance.
GDCR1000C & GDCR1000D:
Model |
Test wire outer diameter |
GDCR1000C |
ø1.6mm~ø16mm |
GDCR1000D |
ø10mm~ø40mm |
Specification
Function | Phase check(positive phase, reverse phase, missing phase), live line check, breakpoint location , line maintenance |
Power supply | DC 3V 2 section alkaline dry cell (LR6), continuous use time of about 70 hours |
Live range | AC 70~1000V, 45~65Hz (sine wave continuous input) |
Test wire size | Outer diameter ø1.6mm~ø16mm or ø10mm~ø40mm(optional) |
LED display | [positive phase] 4 phase detection lights turn on clockwise in turn; [reverse phase] 4 phase detection lights turn on clockwise sequentially. [live line] L1, L2 and L3 lights turn on within the range of voltage setting; [missing phase] L1 or L2 or L3 lights are not on. [open circuit] The L1 or L2 or L3 lights are not on. |
Buzzing | [positive phase] instrument emits intermittent short buzz; [reverse phase] The instrument emits continuous long sounds. |
Battery Indication | POWER indicator lights up after power on; LOW BATTERY lights up when power is insufficient |
Magnetism | There are four magnets attached to the back of the instrument, which are attached to the distribution box and can withstand 800g quality. |
Shut off | After about 5 minutes, the instrument shuts down automatically. |
Dimension | L 70mm* H 75mm* W30mm |
Clamp wire length | 0.6m |
Weight | About 200g (include battery) |
Working condition | -10℃~55℃;<80%rh |
Storage condition | -20℃~60℃;<90%rh |
Measurement max. voltage | AC 1000V |
Dielectric strength | 5.4kV rms |
Max. rated power | 300mVA |
Standards | EN61010-1:2001, EN61010-031:2002, pollution class 2, CAT Ⅲ(600V), transient overvoltage 6000V |
Accessories
Carry case | 1pc |
Battery (LR6) | 2pcs |
Packing list | 1copy |
User’s Guide | 1copy |
Factory test report | 1copy |
Product detail pictures:
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester6.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester2.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester4.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester1.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester5.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester3.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester.jpg)
![China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDCR1000C-Non-contact-Phase-Sequence-Tester7.jpg)
Related Product Guide:
To meet the customers' over-expected pleasure , we have now our solid crew to supply our greatest all round assistance which includes marketing, sales, planning, production, top quality controlling, packing, warehousing and logistics for China High Quality measurement of earth resistance using megger Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot , The product will supply to all over the world, such as: Australia, Washington, Palestine, Welcome to visit our company and factory, there are various products displayed in our showroom that will meet your expectation, meanwhile, if you are convenient to visit our website, our sales staff will try their efforts to provide you the best service
![5 Stars](https://www.hvhipot.com/admin/img/star-icon.png)
The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
![5 Stars](https://www.hvhipot.com/admin/img/star-icon.png)