China High Quality multi phase programmable relay test set Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

China High Quality multi phase programmable relay test set Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We insist on offering premium quality manufacturing with superior business concept, honest product sales as well as finest and fast assistance. it will bring you not only the good quality product or service and huge profit, but the most significant is to occupy the endless market for Power Transformer Distribution Transformer, Capacitor Bank Price, Lightning Impulse Generator, The concept of our corporation is "Sincerity, Speed, Services, and Satisfaction". We're going to follow this concept and gain more and far more customers' pleasure.
China High Quality multi phase programmable relay test set Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot Detail:

Features

A. Working conditions
1. Power supply: AC 220V±10%,50Hz
2. Working environment: Temperature -10℃~40℃; Humidity: ≤85%
3. Atmosphere: 86-106kPa

B. Output power supply
1. AC voltage: 0-220V/3A  Adjustable
2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable
3. DC voltage: 0-220V/3A  Adjustable
4. DC current:0-20A/25V
5. Fixed voltage output: DC 24V/48V/110V/220V
6. Current/Voltage accuracy: ±1%.

C. Performance Index
1. Ammeter and voltmeter: 41/2 digit.
2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms.

D. Functions
1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay.
2. Time relay: Measure start value, return value and action time.
3. Intermediate relay: Measure all kinds of coil with start. Remain start value, return value, holding value and action time of coil intermediate relay.
4. Reclosing relay: Charge test of capacitance, charge time, reclosing time and middle components test.
5. Differential relay: DC Excitation test, Braking test, Volt-ampere characteristic test.
6. Other common relays and LV circuit breaker.

Accessories

Name Qty
GDJB-II secondary injection test set 1 pc
Power cable 1 pc
Test line 6 pcs
Current line 2 pcs
Fuse 4 pcs
Manual 1 copy
Certificate 1 copy

Product detail pictures:

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality multi phase programmable relay test set Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures


Related Product Guide:

We have advanced equipment. Our products are exported to the USA, the UK and so on, enjoying a good reputation among customers for China High Quality multi phase programmable relay test set Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot , The product will supply to all over the world, such as: Turkey, Hungary, Niger, Taking the core concept of "to be the Responsible". We will redound up on society for high quality products and good service. We will initiative to participate in international competition to be a first- class manufacturer of this product in the world.
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Tina from Peru - 2018.12.25 12:43
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Grace from Jeddah - 2017.09.22 11:32

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us