We often persist with the theory "Quality To start with, Prestige Supreme". We are fully committed to delivering our clientele with competitively priced good quality items, prompt delivery and experienced support for Vacuum Capacitance, Discharge Capacitor With Multimeter, Dc Winding Resistance Test, Welcome all nice buyers communicate details of solutions and ideas with us!!
China High Quality Multimeter With Capacitance Testing Suppliers – Partial Discharge Test System GDYT series – HV Hipot Detail:

GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

It includes below components
1. Hipot Test Control Unit GDYD      
2. PD-free Gas type transformer YDQW  
3. Coupling capacitor      
4. Protective resistor             
5. Isolation filter LBQ                   
6. Partial discharge detector 

Features

● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability. 

Specifications

● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions

Model Rated Capacity High Voltage Low Voltage Top cover OD x Height Weight
(KVA) (KV) (KV) (mm) (KG)
GDYT-5/50 5 50 0.22/0.38 320×450 42
GDYT-50/50 50 50 0.22/0.38 850×945 360
GDYT-10/100 10 100 0.22/0.38 570×725 150
GDYT-50/100 50 100 0.22/0.38 850×1000 400
GDYT-100/100 100 100 0.22/0.38 850×1000 800
GDYT-15/150 15 150 0.22/0.38 1165×1400 500
GDYT-75/150 75 150 0.22/0.38 1350×1570 1100
GDYT-150/150 150 150 0.38/0.6 1350×1570 1400
GDYT-20/200 20 200 0.22/0.38 1165×1850 760
GDYT-100/200 100 200 0.22/0.38 1450×1950 1800
GDYT-200/200 200 200 0.38/0.6 1800×1950 3100
GDYT-25/250 25 250 0.22/0.38 1250×2200 1250
GDYT-150/250 150 250 0.38/0.6 1450×2200 1900
GDYT-250/250 250 250 0.38/0.6 2000×2300 3100
GDYT-500/250 500 250 3/6 200×2600 5800
GDYT-1000/250 1000 250 3/6 2200×2600 8200

Product detail pictures:

China High Quality Multimeter With Capacitance Testing Suppliers –  Partial Discharge Test System GDYT series – HV Hipot detail pictures

China High Quality Multimeter With Capacitance Testing Suppliers –  Partial Discharge Test System GDYT series – HV Hipot detail pictures

China High Quality Multimeter With Capacitance Testing Suppliers –  Partial Discharge Test System GDYT series – HV Hipot detail pictures


Related Product Guide:

Our concentrate on is always to consolidate and enhance the excellent and service of present solutions, in the meantime regularly develop new products to meet distinctive customers' demands for China High Quality Multimeter With Capacitance Testing Suppliers – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Indonesia, Miami, Holland, Our mission is "Provide Products with Reliable Quality and Reasonable Prices". We welcome customers from every corner of the world to contact us for future business relationships and achieving mutual success!
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Ellen from Seattle - 2018.06.18 19:26
    The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Louise from Malaysia - 2018.12.14 15:26

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us