We have our own product sales staff, style crew, technical group, QC staff and package staff. We now have strict high quality management procedures for each approach. Also, all of our workers are experienced in printing subject for High Voltage Withstand Test, High Voltage Cable Testing Equipment, Capacitor Power, We've been not pleased while using the present achievements but we are trying finest to innovate to satisfy buyer's much more personalized needs. No matter where you will be from, we have been here to wait for your sort ask for, and welcom to go to our manufacturing facility. Choose us, you can meet your trusted supplier.
China High Quality oil testing equipment Supplier – GDOH-II insulating Oil Gas Content Tester – HV Hipot Detail:

General Information 

GDOH-II Insulating Oil Gas Content Tester is a new generation tester adopts imported high accuracy sensor and the newest sensor technology. It is based on the DL423-91 power industry standard and relevant national standards. It is more practical, more stable and reliable in performance, easy to operate and more suitable for the determination of gas content in ultra-high voltage oil-filled equipment. It is an ideal test equipment for laboratory.

Features

● The all-metal structure avoids the problems of fragility and poor sealing of the glassware tester.
● The application of high precision and high stability imported differential pressure sensor makes the test data more accurate and repeatable.
● The test circuit contains the sensors that measure atmospheric pressure and ambient temperature. No matter where you are, you can automatically measure the ambient temperature and atmospheric pressure at your location, automatically convert to the gas content at 0° under standard atmospheric pressure, and display it directly on the LCD screen
● The unique gas injection anti-standard test program allows you to easily check whether the instrument is calibrated or measured correctly.
● The oil sample test time is short, and all test time takes only about 7 minutes.
● During the test, the operation of the vacuum pump is controlled by the instrument according to the state, which greatly reduces the noise and prolongs the service life of the vacuum pump.
● The instrument can automatically store the last dozen test data, and store the test time, temperature, atmospheric pressure, etc., so that you can easily check the data.
● With printing function, you can print test data according to your requirements.
● The same oil sample can be selected for the number of tests. After the test is completed, the single and average results will be displayed on the display or printed.

Specifications

High-precision electronic differential pressure sensor

Resolution is not less than 0.1%.

Minimum detection limit

No more than 0.2%.

Accuracy

The relative error of the repeated measurement results should not exceed the following values:

Gas content in oil (volume fraction), %

Relative error,%

< 0.5

10

0.5~1.0

8

1.0~3.0

5

>3.0

3

Degassing room temperature control range

5℃ to 70℃ above room temperature

Working power supply

AC 220V±10%,  50Hz

Dimension

450*325*350 mm

Weight

About 20kg

Accessory

Tester 1 set
Power cord 1 piece
Vacuum pump & connector 1 set
3mm stainless steel pipe 1.5m, 0.5m
Syringe connector 1 set
Fuse 10A 3 pieces
M8×1 nut 10 pieces
Seal 10 pieces
Syringe bracket 1 piece
1mL calibration syringe 1 piece
Rotary vane vacuum pump 1 set
Instruction Manual 1 copy
Product certification 1 copy
Factory test report 1 copy
Packing list 1 copy

Product detail pictures:

China High Quality oil testing equipment Supplier –  GDOH-II insulating Oil Gas Content Tester – HV Hipot detail pictures


Related Product Guide:

We have been convinced that with joint attempts, the business enterprise between us will bring us mutual benefits. We could guarantee you product or service good quality and aggressive value for China High Quality oil testing equipment Supplier – GDOH-II insulating Oil Gas Content Tester – HV Hipot , The product will supply to all over the world, such as: Danish, Russia, Armenia, With the effort to keep pace with world's trend, we will always endeavor to meet customers' demands. If you want develop any other new products, we can customize them for you. If you feel interest in any of our products or want develop new products, please feel free to contact us. We are looking forward to forming successful business relationship with customers all over the world.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Donna from St. Petersburg - 2018.12.11 14:13
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Irene from Mauritius - 2017.03.28 16:34

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us