Our company sticks into the basic principle of "Quality is definitely the life of the business, and status may be the soul of it" for Capacitor Spec, Dissipation Factor Tester, Capacitor Power, We welcome new and old customers to contact us by phone or send us inquiries by mail for future business relationships and achieving mutual success.
China High Quality overcurrent protection relay tester Suppliers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot Detail:

Features

A. Working conditions
1. Power supply: AC 220V±10%,50Hz
2. Working environment: Temperature -10℃~40℃; Humidity: ≤85%
3. Atmosphere: 86-106kPa

B. Output power supply
1. AC voltage: 0-220V/3A  Adjustable
2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable
3. DC voltage: 0-220V/3A  Adjustable
4. DC current:0-20A/25V
5. Fixed voltage output: DC 24V/48V/110V/220V
6. Current/Voltage accuracy: ±1%.

C. Performance Index
1. Ammeter and voltmeter: 41/2 digit.
2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms.

D. Functions
1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay.
2. Time relay: Measure start value, return value and action time.
3. Intermediate relay: Measure all kinds of coil with start. Remain start value, return value, holding value and action time of coil intermediate relay.
4. Reclosing relay: Charge test of capacitance, charge time, reclosing time and middle components test.
5. Differential relay: DC Excitation test, Braking test, Volt-ampere characteristic test.
6. Other common relays and LV circuit breaker.

Accessories

Name Qty
GDJB-II secondary injection test set 1 pc
Power cable 1 pc
Test line 6 pcs
Current line 2 pcs
Fuse 4 pcs
Manual 1 copy
Certificate 1 copy

Product detail pictures:

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures


Related Product Guide:

With a positive and progressive attitude to customer's interest, our company continuously improves our product quality to meet the needs of customers and further focuses on safety, reliability, environmental requirements, and innovation of China High Quality overcurrent protection relay tester Suppliers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot , The product will supply to all over the world, such as: Rome, Florence, India, Our company always concentrate on the development of the international market. We now have a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.
  • Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Marjorie from Southampton - 2017.09.22 11:32
    Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Martin Tesch from Belarus - 2018.10.31 10:02

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us