"Sincerity, Innovation, Rigorousness, and Efficiency" will be the persistent conception of our company to the long-term to establish together with customers for mutual reciprocity and mutual gain for Hipot Test Kit, Doble Power Factor Test, Voltage Tester, We sincerely welcome both foreign and domestic business partners, and hope to work with you in the near future!
China High Quality partial discharge test report Manufacturer – Partial Discharge Online Monitoring System of GIS – HV Hipot Detail:

General Information

Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equipment failure and to ensure the normal operation of the system with minimum maintenance cost.

There are many reasons for the deterioration of the dielectric medium, such as ionization corrosion caused by a strong electric field for a long time, insulation wear caused by mechanical high-frequency vibration, aging decomposition of the medium caused by thermal effects, and moisture insulation. The dielectric medium is degraded, and the performance is degraded so that the dielectric breakdown has a development process, which makes the on-line monitoring of insulation practical and effective. The system uses Smart Quick software developed totally by HVHIPOT. It uses advanced high-speed DSP digital processing technology and software. The processing technology makes our monitoring system fast and accurate, which is the most economical and reliable solution for the online monitoring system of GIS.

Monitoring Principle

Through installing UHF sensor on the key components of GIL/GIS, to collect 500MHz-1500MHz electromagnetic wave signal excited by the partial discharge of GIL/GIS in real time. It also collects feature quantities such as amplitude (Q), phase (Φ), frequency (N), and cycle sequence (t) of the partial discharge pulse signal that reaches the trigger condition by detection frequency reduction circuit, high speed sampling circuit and data processing buffer circuit. Event files are generated and uploaded to upper computer expert diagnosis system, to perform event map establishment and monitoring equipment insulation state analysis. 

Partial Discharge Online Monitoring System of GIS01

UHF PD measurement principle

Install the UHF sensor on the busbar part or GIL. The sensor measurement principle diagram is shown in the above figure. The sensor installation is divided into built-in and external modes. Multiple sensors can be installed on one GIS interval or the whole GIL to achieve effective monitoring of different parts. Anoise sensor is required to acquire the background noise and compare it as a background signal during data analysis.

The installation principle of the UHF partial discharge sensor for GIL is the same as that of the GIS and is arranged according to the distance characteristics of the PD signal propagation. The built-in sensor is installed in the pre-installed way of GIL/GIS production. The sensor arrangement should ensure that the partial discharge occurring at any position inside GIL/GIS can be effectively detected. Under this premise, the sensor should be installed in key components of GIL/GIS, including circuit breakers, disconnectors, voltage transformers, busbars, etc.


Product detail pictures:

China High Quality partial discharge test report Manufacturer –  Partial Discharge Online Monitoring System of GIS – HV Hipot detail pictures


Related Product Guide:

We support our prospective buyers with ideal top quality merchandise and superior level provider. Becoming the specialist manufacturer in this sector, we have now attained abundant practical expertise in producing and managing for China High Quality partial discharge test report Manufacturer – Partial Discharge Online Monitoring System of GIS – HV Hipot , The product will supply to all over the world, such as: Nigeria, Belgium, USA, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.
  • We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Bertha from Surabaya - 2018.08.12 12:27
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Maggie from Malawi - 2017.04.18 16:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us