China High Quality pd test of transformer Factory – GDJF-2006 Partial Discharge Analyzer – HV Hipot

China High Quality pd test of transformer Factory – GDJF-2006 Partial Discharge Analyzer – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As a way to ideal meet up with client's desires, all of our operations are strictly performed in line with our motto "High Top quality, Competitive Cost, Fast Service" for Types Of Partial Discharge, Power Transformer Distribution Transformer, Capacitor Ratings, We sincerely welcome overseas buyers to consult for that long-term cooperation as well as the mutual progress.
China High Quality pd test of transformer Factory – GDJF-2006 Partial Discharge Analyzer – HV Hipot Detail:

Features

● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy.
● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage.
● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency.
● Big color LCD screen. Large memory, with USB port.
● With anti-false operation function. Automatic adjusting gain during testing and rectifying.
● Anti-interference design.

Specifications

● Capacitance range: 6pF-250μF
● Sensitivity: <0.02pc (capacitance at 50pF)                  
● Amplifier: 3db low frequency fl 10kHz, 20kHz, 30kHz, 50kHz, 80kHz.   /   3db high frequency fh 100kHz, 200kHz, 300kHz, 400kHz, 500kHz.
● Gain adjustment range>120db, gain difference 20±1db, asymmetry of positive/negative pulse response<1db
● Time window: width 1°-360°, can be rotated at any time.
● Test voltage: 0-200kV, error <3% F.S.
● Acquisition channel: 4 or 6channels/card.
● Input impedance: 1MΩ.
● Max. Sampling rate: 20Mhz.
● AD resolution: 12bit, DC accuracy 0.2%.
● Sampling length of each channel: 8M.
● Triggering mode: Manual, internal triggering, external triggering.
● Bandwidth of acquisition card: 3Mhz(-3db).
● Weight: about 15kg.


Product detail pictures:

China High Quality pd test of transformer Factory –  GDJF-2006 Partial Discharge Analyzer – HV Hipot detail pictures

China High Quality pd test of transformer Factory –  GDJF-2006 Partial Discharge Analyzer – HV Hipot detail pictures


Related Product Guide:

We insist on offering high quality production with good business concept, honest sales and the best and fast service. it will bring you not only the high quality product and huge profit, but the most significant is to occupy the endless market for China High Quality pd test of transformer Factory – GDJF-2006 Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: Bangalore, Mexico, Muscat, We follow up the career and aspiration of our elder generation, and we are eager to open up a new prospect in this field, We insist on "Integrity, Profession, Win-win Cooperation", because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
  • This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Eudora from Borussia Dortmund - 2018.12.22 12:52
    The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Arabela from Sweden - 2018.10.01 14:14

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us