China High Quality pd transformer Exporters – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
China High Quality pd transformer Exporters – GDPD-3000C Portable Partial Discharge Detector – HV Hipot Detail:
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time.
Specification
Hardware
● Processor: high performance intelligent processor.
● Screen: 4.3inch Touch Screen.
● Operation keys: PVE film keyboard.
● Interface:
● 3.5mm stereo headphone interface
● DC LV current charging interface
● USB 2.0 3G wireless network interface
● TF memory card interface
● External probe sensor interface
● TF memory card: 4G-32G.
● Headphones: Min. 8Ω.
● External probe: Ultrasonic probe extension line 250mm.
● Enclosures material: ABS+PC Plastique.
● Weight: 0.7kg;
● Dimension: 241*126*189mm
Operating Environment
● Operation temperature: 0~55℃.
● Operation humidity: 0~90% RH, non-condensing.
● IP rates: 54.
Ultrasonic Sensor Parameters
● Measuring range: -20dBµV~65dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Sensitivity: -65dB.
● Frequency: 40kHz.
● Diameter: 16mm.
● Test source: 25dB~35dB.
TEV Parameters
● Sensor: Capacitive.
● Measuring range: 0dBµV~60dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Max Number of Pulses/Cycle: 655.
● Min number of pulses: 5Hz
Power Supply
● Internal battery: 3.7V, 5.6Ah rechargeable Lithium-ion.
● Typical operating time: approx. 6 hours.
● Battery protection: Auto shutdown time, default 10 mins.
● Rated voltage of charger: 90-264V AC.
● Charging voltage/current: 5V/2.4A.
● Charging Time: approx. 9 hours.
Product detail pictures:



Related Product Guide:
Innovation, good quality and reliability are the core values of our enterprise. These principles today extra than ever form the basis of our success as an internationally active mid-size organization for China High Quality pd transformer Exporters – GDPD-3000C Portable Partial Discharge Detector – HV Hipot , The product will supply to all over the world, such as: UK, Johannesburg, Macedonia, To let customers be more confident in us and get the most comfortable service, we run our company with honesty, sincerity and best quality . We firmly believe that it is our pleasure to help customers to run their business more successfully, and that our professional advice and service can lead to more suitable choice for the customers.

Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
