China High Quality Portable Gas Detector Manufacturers – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot
China High Quality Portable Gas Detector Manufacturers – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot Detail:
Product Description
GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute.
Application
● High Voltage Switch Equipment
● Rotor vane of helicopter
● Gas transmission system
● To detect fire extinguisher
● Ventilation efficiency research of Buildings
● To detect danger
Advantages
● No radiation.
● No need to replace high pressure high pure argon gas regularly.
● No need to approach high pressure gas.
● No need to replace sensors regularly, cost-effective.
● Stable performance, low maintenance cost. No need to make linear calibration every year.
● No affect by moisture and environment pollution.
● High sensitivity, up to 0.01ppmv.
● When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.
Features
● Color TFT In-Cell screen, double display, visual in sunlight.
● Built-in Lithium battery.
● User-defined alarm with sound and light.
● High sensitivity and good stability.
● Fast measurement speed, time is up to 3s.
● Temperature and pressure compensation.
● Only response for SF6 gas, not for other gas.
● Non-gas contact measurement features ensure that no sensor poisoning will occur at any concentration.
● The sensor constant temperature chamber can ensure that the sensor does not have temperature drift at any ambient temperature.
● Small size, easy to carry, suitable for on-site working.
● With gasbag non-slip straps, more comfortable to carry.
● Data storage up to 100groups.
● Super-light aluminum with full shielding shell.
● External package uses engineering plastic, with water-proof, dust-proof.
Specifications
● Measuring principle: Non-dispersive infrared sensor (NDIR)
● Measuring range: 0-2000ppmv SF6 or 0-50ppmv
● Resolution: 0.1ppmv or 0.01ppmv
● Accuracy: ±2%FS(0-1000ppm)
● Repeatability error: ≤±1%
● Sensitivity: 0.1ppmv
● Response time: ≤2s
● Recovery time: ≤5s
● Stability: ≤±20ppm, more than 1000hours
● Zero shift: ≤±1%(F.S/year)
● Linear error: ≤±1%
● Storage temperature: -20~+60℃
● Operation temperature: -20~+50℃
● Sampling mode: Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min.
● Working voltage: 220VAC±10%, 50Hz Or Built-in Li-battery, 8hours working.
● Dimension: 160×220×70mm, hand gun 106mm*170mm*120mm.
● Weight: main unit about 1.5kg, hand gun about 0.5kg
Product detail pictures:
Related Product Guide:
All we do is always involved with our tenet " Consumer initial, Trust first, devoting within the food stuff packaging and environmental defense for China High Quality Portable Gas Detector Manufacturers – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot , The product will supply to all over the world, such as: Latvia, Slovenia, Israel, Faced with the vitality of the global wave of economic integration, we are confident with our high-quality products and sincerely service to all our customers and wish we can cooperate with you to create a brilliant future.
By Laurel from Angola - 2018.12.10 19:03
Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
By Stephen from Costa rica - 2017.04.08 14:55