China High Quality Portable High Voltage Impulse Generator Manufacturer – GDOT-100D 100kV Insulation Oil Tester – HV Hipot
China High Quality Portable High Voltage Impulse Generator Manufacturer – GDOT-100D 100kV Insulation Oil Tester – HV Hipot Detail:
General Information
In power system, railway system and large petrochemical industrial enterprises all have a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type.
Dielectric strength test for insulating oil is a routine test which shall be measured.
In order to meet the market needs. Our company self-developed and produced GDOT series dielectric strength tester for insulation oil according to national standard GB/T5072002, industrial standard DL429.991 and the latest electric power industry standard DL/T846.7- 2004.
The instrument use single chip microcomputer as the core, to achieve full automatic testing and high precision measurement, greatly improves the work efficiency and also reduce the labor intensity of the workers greatly.
Features
● With microprocessor, three cups in one, automatically complete boosting, holding, stirring, static releasing, calculation and printing.
● Enable to carry out oil circulating withstand voltage test in the range of 0-100KV.
● Large screen LCD display.
● Simple to operate, automatically complete 1-3 oil samples withstanding voltage test according to the settings. Each oil sample will be automatically stored for each breakdown voltage value and cycle number. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil sample.
● This series has strong applicability, not only can be used in laboratories, but also be used in outdoor fields. The instrument also has strong anti-interference ability and can work normally in strong electromagnetic field environment. It is very suitable for use in departments with more oil samples and tight test time.
● With over-voltage, over-current, zero return protective function, it can ensure the safety of operators and device at normal use.
● Increasing speed can be set according to different test standard.
Specifications
|
Output voltage |
0-100kV |
|
Power distortion rate |
<3% |
|
Voltage increasing speed |
2.0,2.5,3.0,3.5kV/s (adjustable) |
|
Voltage measurement error |
±3% |
|
Capacity |
1.5kVA |
|
Power input |
AC220V± 10%, 50Hz±1Hz |
|
Power |
<200W |
|
Working temperature |
0℃-+40℃ |
|
Oil cup volume |
200mL (400mL optional) |
|
Electrode spacing |
2.5mm |
|
Humidity |
<80%RH |
|
Dimension |
470*430*480mm |
|
Weight |
49 kg |
Product detail pictures:
Related Product Guide:
Fast and fantastic quotations, informed advisers to help you choose the correct products that suits all your needs, a short manufacturing time, responsible good quality control and distinct companies for paying and shipping affairs for China High Quality Portable High Voltage Impulse Generator Manufacturer – GDOT-100D 100kV Insulation Oil Tester – HV Hipot , The product will supply to all over the world, such as: Gabon, Zambia, India, We put the product quality and customer's benefits to the first place. Our experienced salesmen supply prompt and efficient service. Quality control group make sure the best quality. We believe quality comes from detail. If you have demand, let us work together to get success.