In the past few years, our business absorbed and digested advanced technologies both equally at home and abroad. In the meantime, our company staffs a group of experts devoted to your advancement of Oil Tan Delta Test, Simulate Lightning Impulse, Waveform Generators, Special emphasis on the packaging of products to avoid any damage during transportation,Detailed attention to the valuable feedback and suggestions of our esteemed clients.
China High Quality power usage meter test Exporters – GDYM-1A Single Phase Electric Energy Meter Calibrator – HV Hipot Detail:

Product Description

GDYM-1A Single phase Electric Energy Meter Calibrator is multi-parameter measuring instrument which is full digital, mullti-function and high precision. It is not only enable to calibrating the error, but also to measure voltage, current effective value, active power, reactive power, apparent power, power frequency, power factor, phase relationship, etc. It is especially suitable for calibrating the measurement accuracy of Single-phase electric energy meter in the power supply unit.

Simple and quick operation, all operating procedures are displayed on the screen.

Features

● To calibrate the electric energy meter of measuring system and measure the low voltage ratio.
● Using latest 32 bit 150MHz DPS core technology, 16 bit high precision converter, the error is more stable and accuracy is higher (this has qualitative difference with single-phase calibrator with meter chip).
● Large colorful LCD screen, displays calibrating setting parameters, harmonic, electrical parameters, error and all measuring data dynamically.
● Current clamp is used to simulate current generated by load, which simplified the field working and improved the work efficiency. The current of the terminal and the clamp as well as their power and power sum will be displayed at the same time.
● Using a 500A clamp and a small current clamp to measure the ratio of low voltage CT.
● Measure harmonic data from 2-43 times, current and voltage will real-time display each waveform, which helps to judge the on-site state.
● Calculating the constant of energy meter in one electric energy pulse period.
● Save data for 1000 meters.
● Connect with PC by RS232 series communication interface.
● With a low frequency pulse output, convenient for self-checking and inspection.

Special Features

● The calibrator will alarm by sound and light when supplying 380V to voltage test line.
● When the simulation load current line is wrong connected to the neutral line of the meter, the first automatic protection will not output current. When making the fault connection again, the secondary protective fuse will be burn out, which applies absolutely protection. The calibrator will recover after replacing the fuse.
● The fuse will be burn out when the impulse line hit 220V, the calibrator will recover after replacing the fuse.

Specifications

 

Measurement Range

Accuracy

Voltage

10-300V

±0.1%

Simulation Current

5A

±20%

Current Clamp

100A, 500A

±0.3%, ±0.5%

Current Terminal

0.05-10 A

±0.1%

Power

Current Clamp

100A, 500A

±0.3%, ± 0.5%

Terminal

10A

±0.1%

Phase Angle

-180–+180°

±0.1°

Frequency

45-55Hz

±0.01Hz

Electric Energy

100A Clamp(small)

0.25A-110A

±0.3%, ±0.5%

500A Clamp

25-1000A

±0.5%

Display Range

100A Current Clamp: 0.01A-110A

Terminal: 0.01A-10A

Electric Energy Pulse

FL=1000 imp/kW.h

Working Voltage

AC 100 - 300 V

Working Temperature

-25℃~45℃

Working Humidity

<95% No condensation

Weight

<1kg

Volume

215*105*70mm

Accessories

GDYM-1A Calibrator 1 set
100A clamp meter 1 pieces
Management Software (CD-ROM) 1 piece
Electronic meter pulse line 1 piece
Voltage cable 1 piece
Power cable 1 piece
232 communication line 1 piece
Photoelectric head 1 piece
0.5A Fuse 1 piece
Instrument case 1 piece
Manual 1 copy

Product detail pictures:

China High Quality power usage meter test Exporters –  GDYM-1A Single Phase Electric Energy Meter Calibrator – HV Hipot detail pictures

China High Quality power usage meter test Exporters –  GDYM-1A Single Phase Electric Energy Meter Calibrator – HV Hipot detail pictures


Related Product Guide:

Good quality comes initial; company is foremost; small business is cooperation" is our business philosophy which is frequently observed and pursued by our business for China High Quality power usage meter test Exporters – GDYM-1A Single Phase Electric Energy Meter Calibrator – HV Hipot , The product will supply to all over the world, such as: Greece, Swansea, United States, To meet the requirements of individual customers for each bit more perfect service and stable quality products. We warmly welcome customers around the world to visit us, with our multi-faceted cooperation, and jointly develop new markets, create a brilliant future!
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Margaret from Nigeria - 2018.06.18 19:26
    As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Nana from Georgia - 2017.09.22 11:32