China High Quality ppm test of transformer oil Suppliers – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
China High Quality ppm test of transformer oil Suppliers – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.
GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.
Features
● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.
Specification
Measuring range | 0-200mN/m |
Accuracy | 0.1% of the reading±0.1 mN/m |
Resolution | 0.1mN/m |
Sensitivity | 0.1mN/m |
Power supply | AC220V±20%,50Hz±10% |
Maximum power consumption | 20W |
Environmental temperature | 10~30℃(25℃ is the best) |
Environmental humidity | ≤85% RH |
Dimension | 200×300×330(mm) |
Weight | 6kg |
Product detail pictures:


Related Product Guide:
Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for China High Quality ppm test of transformer oil Suppliers – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Milan, Melbourne, Norwegian, In the new century, we promote our enterprise spirit "United, diligent, high efficiency, innovation", and stick to our policy"basing on quality, be enterprising, striking for first class brand". We would take this golden opportunity to create bright future.

We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
