China High Quality protection relays used in substation Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

China High Quality protection relays used in substation Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our leading technology also as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future jointly with your esteemed company for Ac Tester, Testing Of Instrument Transformer, 20 Kv Generator Tan Delta Test, We warmly welcome friends from all walks of existence to cooperate with us.
China High Quality protection relays used in substation Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot Detail:

Features

A. Working conditions
1. Power supply: AC 220V±10%,50Hz
2. Working environment: Temperature -10℃~40℃; Humidity: ≤85%
3. Atmosphere: 86-106kPa

B. Output power supply
1. AC voltage: 0-220V/3A  Adjustable
2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable
3. DC voltage: 0-220V/3A  Adjustable
4. DC current:0-20A/25V
5. Fixed voltage output: DC 24V/48V/110V/220V
6. Current/Voltage accuracy: ±1%.

C. Performance Index
1. Ammeter and voltmeter: 41/2 digit.
2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms.

D. Functions
1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay.
2. Time relay: Measure start value, return value and action time.
3. Intermediate relay: Measure all kinds of coil with start. Remain start value, return value, holding value and action time of coil intermediate relay.
4. Reclosing relay: Charge test of capacitance, charge time, reclosing time and middle components test.
5. Differential relay: DC Excitation test, Braking test, Volt-ampere characteristic test.
6. Other common relays and LV circuit breaker.

Accessories

Name Qty
GDJB-II secondary injection test set 1 pc
Power cable 1 pc
Test line 6 pcs
Current line 2 pcs
Fuse 4 pcs
Manual 1 copy
Certificate 1 copy

Product detail pictures:

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures


Related Product Guide:

Dedicated to strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction for China High Quality protection relays used in substation Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot , The product will supply to all over the world, such as: South Korea, Georgia, Irish, We can meet the various needs of customers at home and abroad. We welcome new and old customers to come to consult & negotiate with us. Your satisfaction is our motivation! Allow us to work together to write a brilliant new chapter!
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Elsie from Boston - 2017.03.28 16:34
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Salome from America - 2018.05.22 12:13

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us