China High Quality Pulse Generator Impulus Signallar Manbaai Suppliers – Impulse Voltage Test System – HV Hipot
China High Quality Pulse Generator Impulus Signallar Manbaai Suppliers – Impulse Voltage Test System – HV Hipot Detail:
Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
Impulse voltage grade | 100kV-7200kV |
Standard lightning wave | 1.2±30%/50±20%µS |
Peak oscillation | <5% |
Standard switching wave | 250±20%/2500±60%µS |
Virtual front time of oscillating lightning wave | ≤15µS |
Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
The minimum output voltage | ≥10%Un |
Charging voltage instability | <±1% |
Synchronizing range | ≥20% |
Synchronous discharge error rate | <2% |
Ignition range | 10%~100% |
Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
Generator efficiency: lightning wave (no load) | ≥90% |
Time to chopping | 2~5µS |
Product detail pictures:



Related Product Guide:
"Quality very first, Honesty as base, Sincere assistance and mutual profit" is our idea, in an effort to create consistently and pursue the excellence for China High Quality Pulse Generator Impulus Signallar Manbaai Suppliers – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: Mauritania, Leicester, Egypt, We are in continuous service to our growing local and international clients. We aim to be worldwide leader in this industry and with this mind; it is our great pleasure to serve and bringing the highest satisfaction rates among the growing market.

We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
