China High Quality relay test set unit Manufacturers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

China High Quality relay test set unit Manufacturers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With reliable quality process, good reputation and perfect customer service, the series of products produced by our company are exported to many countries and regions for Unit Of Measurement For Capacitor, Capacitor Discharge Test, Higher Capacitance, Welcome throughout the world buyers to speak to us for organization and long-term cooperation. We're going to be your reliable partner and supplier.
China High Quality relay test set unit Manufacturers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot Detail:

Features

A. Working conditions
1. Power supply: AC 220V±10%,50Hz
2. Working environment: Temperature -10℃~40℃; Humidity: ≤85%
3. Atmosphere: 86-106kPa

B. Output power supply
1. AC voltage: 0-220V/3A  Adjustable
2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable
3. DC voltage: 0-220V/3A  Adjustable
4. DC current:0-20A/25V
5. Fixed voltage output: DC 24V/48V/110V/220V
6. Current/Voltage accuracy: ±1%.

C. Performance Index
1. Ammeter and voltmeter: 41/2 digit.
2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms.

D. Functions
1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay.
2. Time relay: Measure start value, return value and action time.
3. Intermediate relay: Measure all kinds of coil with start. Remain start value, return value, holding value and action time of coil intermediate relay.
4. Reclosing relay: Charge test of capacitance, charge time, reclosing time and middle components test.
5. Differential relay: DC Excitation test, Braking test, Volt-ampere characteristic test.
6. Other common relays and LV circuit breaker.

Accessories

Name Qty
GDJB-II secondary injection test set 1 pc
Power cable 1 pc
Test line 6 pcs
Current line 2 pcs
Fuse 4 pcs
Manual 1 copy
Certificate 1 copy

Product detail pictures:

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures

China High Quality relay test set unit Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot detail pictures


Related Product Guide:

Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for China High Quality relay test set unit Manufacturers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot , The product will supply to all over the world, such as: Czech Republic, United States, Czech Republic, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Catherine from Islamabad - 2017.02.28 14:19
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Jean from Oman - 2017.03.07 13:42

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us