China High Quality resistance box Factories – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

China High Quality resistance box Factories – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Bear "Customer initially, High-quality first" in mind, we work closely with our prospects and supply them with efficient and specialist companies for Capacitor Discharge Unit, Transformer Capacitor, Hipot Test Voltage, On account of superior excellent and aggressive rate , we will be the sector leader, make sure you don’t hesitate to contact us by cellular phone or email, if you're fascinated in almost any of our items.
China High Quality resistance box Factories – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot Detail:

General Information

GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can deal with all kinds of test requirements, can measure the grounding resistance value of the large size ground down lead, flexible measuring the grounding resistance value of the single point and grid grounding and all kinds of complex grounding structure, no need to disconnect any parallel connection earth pole when measuring parallel grounding system, greatly improves the convenience of measurement, for the grounding performance test provides a perfect solution.

GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is composed of host machine, current clamp(double clamp), test wires, auxiliary ground rod, data software and communication wires and so on. The large LCD display of host machine with white backlight and bar graph indication that can be seen clearly. The tester has storage function, clock function, and automatically stores 2000 groups of test results containing date and time.The tester with Bluetooth communication function supporting Android system. After the installation of APP, can test or read test records in the mobile terminal, bringing a new experience. The tester equip USB interface, and the stored data can be uploaded to the PC through the USB interface. The communication software can realize the functions of reading, consulting, saving, reporting and printing of the historical record data. Widely used in power, telecommunications, meteorology, oil fields, construction, lightning protection and industrial electrical equipment.

Features

● Unique design of the jack indicator light, accurate indication of the jack position, avoid operation error.

● Gears function selection knob, various test methods are displayed, making the operation simple and fast.

● The tester has Bluetooth communication function and supports Android system. Users can use mobile terminal to test operation or read test results containing date and time very conveniently.

● The instrument case adopts waterproof protection box, which is strong, safe and durable for anti-collision, anti-fall and waterproof (protection grade IP65), especially suitable for use in outdoor construction sites.

● The meter is equipped with large capacity rechargeable lithium battery pack. And with USB interface to upload data function.

Specifications

Basic conditions & Work conditions

Influence Quantity Base Condition Working Conditions Remark
Ambient Temp 23℃±1℃ -10℃-40℃ —-
Ambient Humidity 40%-60% <80% —-
Working Voltage 7.8V±0.1V DC 7.8V±0.6V —-
Auxiliary Earth Resistance <100Ω <5kΩ  
Interference Voltage Should avoid <20V  
Interference Current Should avoid <2A  
Electrode Distance when  measuring R a>5d a>5d  
Electrode Distance when  measuring ρ a>20h a>20h  

General specification

Function Measure grounding resistance, soil resistivity; DC resistance, earth voltage, alternating current , leakage current
Power Supply DC 7.4V 2600mAh rechargeable lithium battery, full of about 8.4V
Backlight Controllable screen backlight, suitable for dim places
Measuring Method DC resistance DC resistance 2-wire method
DC resistance 4-wire method
Earth resistance Earth resistance 2-wire method
Earth resistance 3-wire method
Earth resistance 4-wire method
Earth resistance single clamp 3-wire method (selection method)
Earth resistance single clamp 4-wire method (selection method)
Earth resistance double clamp method
Soil resistivity(Wenner method)
Earth current Current clamp measurement
Earth voltage Average rectification
Test Voltage Wave Sine wave
Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current AC 250mA max
Open-circuit Test Current AC 40V max
Electrode Distance Range 1m-100m
Display Mode 4-digital large LCD display, with screen backlight
Measuring Indicator During measurement, LED flash indicator, LCD countdown display
LCD Frame Dimension 128mm×75mm
LCD display area 124mm×67mm
Instrument Dimension 280mm(L) X 260mm(W) X 160mm(H)
CT Size 223mm X 120mm X 39mm
Test Wire 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire 2 wires: each for red 1.6m and black 1.6m
Auxiliary Grounding Rod 4PCS: Φ10mm X150mm
Current Clamp 2PCS :1 blue-black plug and 1 red-black plug
Clamp Caliber Φ70mm
Clamp Lead Wire 2m
Measuring Rate AC current: about 2 times/second
Earth Voltage: about 2 times/second
Earth resistance: about 7 seconds/time
Measuring Times Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Line Voltage Measurement below AC 600V
Communication Interface Bluetooth module, USB interface, storage data can be uploaded to computer, saved or printed.
Communication Wire USB communication wire x1pcs, with length 1.5m
Data Hold Data hold function: “HOLD” symbol display
Data Storage 2000 groups, “MEM” storage indicator, “FULL” symbol flash display storage is full
Data Access Data read function:”READ” symbol display
Overflow Display Exceed measuring range overflow function: “OL”symbol display
Low Current Indicator of Current clamp Measurement with selection method or double clamp, the current signal received by CT2 is lower than 0.5mA,will display“    ”, and should check the clamping direction of the CT2 current clamp
Interference Test Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
Auxiliary Grounding Test With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function Measuring value exceeds alarm setting value, will make out ”Toot-toot-toot” alarm sound.
Battery Voltage While battery voltage decreases to around 7.2V±0.1V, will display battery voltage low symbol, and reminding to replace the battery
Automatic Shutdown Automatically shut down after 15 minutes of power on
Working Current Backlight: 25mA Max(only backlight power consumption)
Standby:25mA Max(Backlight off after power on)
Measurement:150mA Max(Backlight shut off)
Weight Tester: 2290g
Current Clamp:1100g(2pcs)
Total weight: 6800g(include all accessories)
Working Temperature & Humidity -10℃-40℃, below 80%rh
Storage temperature & humidity -20℃-60℃, below 70%rh
Protection Level IP65(close the case)
Overload Protection Measure earth resistance: between each interfaces of C(H)-E, P(S)-ES, AC 280V/3 seconds
Insulation Resistance Over 20MΩ(between circuit and outside shell is 500V)
Withstanding Voltage AC 3700V/rms. (Between circuit and outside shell)
Electromagnetic Features IEC61326(EMC)
Protection Type IEC61010-1(CAT Ⅲ 300V, CAT IV 150V, Pollution 2);
IEC61010-031;
IEC61557-1(Earth resistance);
IEC61557-5(Soil resistivity);
JJG 366-2004(Grounding resistance meter)
JJG 1054-2009(Clamp grounding resistance meter)

Product detail pictures:

China High Quality resistance box Factories –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot detail pictures

China High Quality resistance box Factories –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot detail pictures

China High Quality resistance box Factories –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot detail pictures

China High Quality resistance box Factories –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot detail pictures

China High Quality resistance box Factories –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot detail pictures

China High Quality resistance box Factories –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot detail pictures


Related Product Guide:

We goal to understand excellent disfigurement from the manufacturing and supply the top support to domestic and abroad clients wholeheartedly for China High Quality resistance box Factories – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot , The product will supply to all over the world, such as: Philippines, Sweden, Chile, We win many reliable customers by rich experience, advanced equipments, skilled teams, strict quality control and best service. We can guarantee all our products. Customers' benefit and satisfaction are always our biggest goal. Please contact us. Give us a chance, give you a surprise.
  • This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Melissa from Liverpool - 2018.09.08 17:09
    In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By Brook from Muscat - 2017.09.22 11:32

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us