China High Quality Sf6 Gas Analyser Manufacturer – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot

China High Quality Sf6 Gas Analyser Manufacturer – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We constantly think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body along with the living for Standard Capacitor, Power Factor Meter, Ac Voltage Capacitor, We are also constantly looking to establish relationship with new suppliers to provide innovative and smart solution to our valued customers.
China High Quality Sf6 Gas Analyser Manufacturer – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot Detail:

General Information

GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content. The core component with  NDIR sensor produced by European sensor company to test SF6 gas purity, RC sensor produced by Vaisala, Finland to test dew point, NDIR sensor produced by Smartgas, Germany to test SF6 gas decomposition product–CF4. the air sensor adopts itg technology. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics.

Application

● SF6 analysis fo power system
● SF6 gas cylinder gas quality test
● Quality test of SF6 gas for recovery and reuse
● High purity gas manufacturing
● Semiconductor industry dry gas supply
● Research and development use 

Features

● With imported high-precision sensor and self-calibration function, test results are more accurate all year round.
● With polymer material design throughout gas pipeline from Legris, Camozzi and Swagelok, ensure no wall-clinging condition,and fast test speed.
● Oil-free stainless steel regulating valve is adopted to ensure test accuracy.
● Advanced software algorithm improves the test accuracy of imported sensors.
● With flexible case configuration. User can assemble spare parts more easily.
● Power on to detect, no need for oscillation.
● Temperature conversion and pressure data correction.
● Fuzzy computing technology.
● High-power lithium power supply system can realize AC DC double power supply. No need for on-site AC power supply. Lithium battery can work continuously for more than 8 hours alone.
● Anti-electromagnetic interference circuit design, to ensure the reliability of products.
● USB communication, serial communication and wireless communication modules can be extended to realize PC communication and printing functions. (optional)
● Mass storage, which can realize the storage function of 1000 groups of data.
● Gas path pretreatment function can purify the test pipeline before the field test work, which shortens the test time. (optional)
● With environment protection function. The instrument has a test gas recovery function, which can recycle the measured sulfur hexafluoride gas. (optional)
● The purity measurement accuracy is 0.5% in the full range, which can be applied to measure high concentration SF6 gas and 70% SF6 gas.
● The display of the best test flow area is clear and intuitive. Users can adjust the gas flow directly and quickly.
● The air inlet adopts the design of miniature self-sealing joint, so the measured air path will not leak when it is broken.

Specification

GDP-311PCAW 3-in-1 SF6 Quality Analyzer application


Product detail pictures:

China High Quality Sf6 Gas Analyser Manufacturer –  GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot detail pictures


Related Product Guide:

owing to excellent assistance, a variety of high quality products and solutions, aggressive costs and efficient delivery, we take pleasure in an excellent popularity amongst our customers. We are an energetic business with wide market for China High Quality Sf6 Gas Analyser Manufacturer – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot , The product will supply to all over the world, such as: Algeria, Manila, Estonia, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Antonio from The Swiss - 2017.09.09 10:18
    A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Odelia from Toronto - 2017.09.16 13:44

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us