China High Quality Sf6 Gas Detector 0.1 Ppm Supplier – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot
China High Quality Sf6 Gas Detector 0.1 Ppm Supplier – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot Detail:
General Information
GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content. The core component with NDIR sensor produced by European sensor company to test SF6 gas purity, RC sensor produced by Vaisala, Finland to test dew point, NDIR sensor produced by Smartgas, Germany to test SF6 gas decomposition product–CF4. the air sensor adopts itg technology. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics.
Application
● SF6 analysis fo power system
● SF6 gas cylinder gas quality test
● Quality test of SF6 gas for recovery and reuse
● High purity gas manufacturing
● Semiconductor industry dry gas supply
● Research and development use
Features
● With imported high-precision sensor and self-calibration function, test results are more accurate all year round.
● With polymer material design throughout gas pipeline from Legris, Camozzi and Swagelok, ensure no wall-clinging condition,and fast test speed.
● Oil-free stainless steel regulating valve is adopted to ensure test accuracy.
● Advanced software algorithm improves the test accuracy of imported sensors.
● With flexible case configuration. User can assemble spare parts more easily.
● Power on to detect, no need for oscillation.
● Temperature conversion and pressure data correction.
● Fuzzy computing technology.
● High-power lithium power supply system can realize AC DC double power supply. No need for on-site AC power supply. Lithium battery can work continuously for more than 8 hours alone.
● Anti-electromagnetic interference circuit design, to ensure the reliability of products.
● USB communication, serial communication and wireless communication modules can be extended to realize PC communication and printing functions. (optional)
● Mass storage, which can realize the storage function of 1000 groups of data.
● Gas path pretreatment function can purify the test pipeline before the field test work, which shortens the test time. (optional)
● With environment protection function. The instrument has a test gas recovery function, which can recycle the measured sulfur hexafluoride gas. (optional)
● The purity measurement accuracy is 0.5% in the full range, which can be applied to measure high concentration SF6 gas and 70% SF6 gas.
● The display of the best test flow area is clear and intuitive. Users can adjust the gas flow directly and quickly.
● The air inlet adopts the design of miniature self-sealing joint, so the measured air path will not leak when it is broken.
Specification
Product detail pictures:

Related Product Guide:
As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for China High Quality Sf6 Gas Detector 0.1 Ppm Supplier – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot , The product will supply to all over the world, such as: Manchester, Plymouth, Kenya, It is our customers' satisfaction over our products and services that always inspires us to do better in this business. We build mutually beneficial relationship with our clients by giving them large selection of premium car parts at marked down prices. We provide wholesale prices on all our quality parts so you are guaranteed greater savings.

Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
