China High Quality Sheath Fault For High Voltage Cable Manufacturer – GD-2134A Cable Identifier – HV Hipot
China High Quality Sheath Fault For High Voltage Cable Manufacturer – GD-2134A Cable Identifier – HV Hipot Detail:
The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables.
Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable!
Features
● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry.
● Suitable for on-site identification of de-energized cables.
● Both transmitter and handheld receiver are used during identification.
● The transmitter uses the principle of pulse current to inject a pulse current signal with a maximum value of 30A into the cable core, which generates electromagnetic field around the target cable.
● The handheld receiver can accurately measure the electromagnetic field signal through the induction clamp. Because of the directionality of current, the signal of magnetic field also has directionality.
● 2*1.5V AA (No. 5) dry batteries are used in the handheld receiver. It is necessary to avoid mixing old and new batteries, check battery power regularly, and unload batteries when long-term no use of the instrument.
● Built-in large capacity lithium battery for transmitter. When the instrument is not used for a long time, it is recommended that the batteries be charged and maintained every other month in order to avoid battery self-discharge depletion and damage. Please turn off the transmitter during charging. After plugging in the special power adapter, the built-in battery is charged with AC220V, 50Hz power supply. The transmitter automatically controls the charging process and displays the “Charging in progress”, “Full up” and the percentage of remaining electricity in the power indicator screen.
Specifications
Transmitter
● Working power supply: built-in 12V/2.6Ah lithium ion battery.
● Indication: battery power indication.
● Impulse voltage: 500V.
● Impulse current: Max. 30A (depend on circuit resistance).
● Impulse frequency: 15 times/min.
● Impulse width: 10ms.
● On-site continuous working hours: >10H.
● Display: positive LCD display, clear display in sunlight.
● Working temperature: -25℃~60℃.
● Humidity: ≤80% RH, no condensation.
● Dimension & weight: 180*110*100mm, 1250g.
Receiver
● Working power supply: 2*1.5V AA (No. 5) dry batteries.
● Indication: signal strength indication.
● Clamp: inner diameter Ø180mm, flexible clamp.
● Gain adjustment: 10 gears (-3dB…..24dB).
● On-site continuous working hours: >50H.
● Display: High-bright LED lights for clear display in the sun.
● Working temperature: -25℃~60℃.
● Humidity: ≤80% RH, no condensation.
● Dimension & weight: 150*80*40mm, 220g.
Product detail pictures:
Related Product Guide:
Bear "Customer first, Quality first" in mind, we work closely with our customers and provide them with efficient and professional services for China High Quality Sheath Fault For High Voltage Cable Manufacturer – GD-2134A Cable Identifier – HV Hipot , The product will supply to all over the world, such as: Ukraine, Honduras, Serbia, Aiming to grow to be by far the most experienced supplier within this sector in Uganda, we keep researching on the creating procedure and raising the high quality of our principal merchandise. Till now, the merchandise list has been updated on a regular basis and attracted customers from around the globe. In depth data can be obtained in our web page and you'll be served with good quality consultant service by our after-sale team. They're about to make it possible for you to get complete acknowledge about our things and make a satisfied negotiation. Small business check out to our factory in Uganda can also be welcome at any time. Hope to obtain your inquiries to get a happy co-operation.
By Heloise from Denmark - 2018.11.06 10:04
Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
By Octavia from Nigeria - 2018.07.27 12:26