China High Quality Simulate Lightning Impulse Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot
China High Quality Simulate Lightning Impulse Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot Detail:
General Information
In power system, railway system and large petrochemical industrial enterprises all have a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type.
Dielectric strength test for insulating oil is a routine test which shall be measured.
In order to meet the market needs. Our company self-developed and produced GDOT series dielectric strength tester for insulation oil according to national standard GB/T5072002, industrial standard DL429.991 and the latest electric power industry standard DL/T846.7- 2004.
The instrument use single chip microcomputer as the core, to achieve full automatic testing and high precision measurement, greatly improves the work efficiency and also reduce the labor intensity of the workers greatly.
Features
● With microprocessor, three cups in one, automatically complete boosting, holding, stirring, static releasing, calculation and printing.
● Enable to carry out oil circulating withstand voltage test in the range of 0-100KV.
● Large screen LCD display.
● Simple to operate, automatically complete 1-3 oil samples withstanding voltage test according to the settings. Each oil sample will be automatically stored for each breakdown voltage value and cycle number. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil sample.
● This series has strong applicability, not only can be used in laboratories, but also be used in outdoor fields. The instrument also has strong anti-interference ability and can work normally in strong electromagnetic field environment. It is very suitable for use in departments with more oil samples and tight test time.
● With over-voltage, over-current, zero return protective function, it can ensure the safety of operators and device at normal use.
● Increasing speed can be set according to different test standard.
Specifications
Output voltage |
0-100kV |
Power distortion rate |
<3% |
Voltage increasing speed |
2.0,2.5,3.0,3.5kV/s (adjustable) |
Voltage measurement error |
±3% |
Capacity |
1.5kVA |
Power input |
AC220V± 10%, 50Hz±1Hz |
Power |
<200W |
Working temperature |
0℃-+40℃ |
Oil cup volume |
200mL (400mL optional) |
Electrode spacing |
2.5mm |
Humidity |
<80%RH |
Dimension |
470*430*480mm |
Weight |
49 kg |
Product detail pictures:

Related Product Guide:
Our organization sticks to your principle of "Quality may be the life of your organization, and reputation will be the soul of it" for China High Quality Simulate Lightning Impulse Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot , The product will supply to all over the world, such as: Los Angeles, Greece, Madagascar, Upon today, we have customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to provide the highest quality products with best price. We are looking forward to doing business with you!

This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
