China High Quality soil resistivity tester Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
China High Quality soil resistivity tester Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot Detail:
General Information
GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply can be obtained. There are four strong magnets on the back of the instrument, which can be attached to the distribution box for use.
GDCR1000C, GDCR1000D non-contact phase tester has the functions of looping inspection, simple power inspection, circuit breaking search, breakpoint location, line maintenance and so on.
GDCR1000C, GDCR1000D non-contact phase detector detection is fast, convenient and easy to display at a glance, greatly improving the safety of field testing, effectively protecting the personal safety of operators, and increasing productivity! It is a safety instrument for three-phase power supply phase sequence, motor detection and line maintenance.
GDCR1000C & GDCR1000D:
Model |
Test wire outer diameter |
GDCR1000C |
ø1.6mm~ø16mm |
GDCR1000D |
ø10mm~ø40mm |
Specification
Function | Phase check(positive phase, reverse phase, missing phase), live line check, breakpoint location , line maintenance |
Power supply | DC 3V 2 section alkaline dry cell (LR6), continuous use time of about 70 hours |
Live range | AC 70~1000V, 45~65Hz (sine wave continuous input) |
Test wire size | Outer diameter ø1.6mm~ø16mm or ø10mm~ø40mm(optional) |
LED display | [positive phase] 4 phase detection lights turn on clockwise in turn; [reverse phase] 4 phase detection lights turn on clockwise sequentially. [live line] L1, L2 and L3 lights turn on within the range of voltage setting; [missing phase] L1 or L2 or L3 lights are not on. [open circuit] The L1 or L2 or L3 lights are not on. |
Buzzing | [positive phase] instrument emits intermittent short buzz; [reverse phase] The instrument emits continuous long sounds. |
Battery Indication | POWER indicator lights up after power on; LOW BATTERY lights up when power is insufficient |
Magnetism | There are four magnets attached to the back of the instrument, which are attached to the distribution box and can withstand 800g quality. |
Shut off | After about 5 minutes, the instrument shuts down automatically. |
Dimension | L 70mm* H 75mm* W30mm |
Clamp wire length | 0.6m |
Weight | About 200g (include battery) |
Working condition | -10℃~55℃;<80%rh |
Storage condition | -20℃~60℃;<90%rh |
Measurement max. voltage | AC 1000V |
Dielectric strength | 5.4kV rms |
Max. rated power | 300mVA |
Standards | EN61010-1:2001, EN61010-031:2002, pollution class 2, CAT Ⅲ(600V), transient overvoltage 6000V |
Accessories
Carry case | 1pc |
Battery (LR6) | 2pcs |
Packing list | 1copy |
User’s Guide | 1copy |
Factory test report | 1copy |
Product detail pictures:








Related Product Guide:
Our merchandise are commonly recognized and reliable by customers and can meet constantly developing economic and social desires for China High Quality soil resistivity tester Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot , The product will supply to all over the world, such as: Nigeria, Turkey, Brazil, We can meet the various needs of customers at home and abroad. We welcome new and old customers to come to consult & negotiate with us. Your satisfaction is our motivation! Let us work together to write a brilliant new chapter!

Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
