China High Quality Step Pulse Generator Suppliers – Impulse Voltage Test System – HV Hipot
China High Quality Step Pulse Generator Suppliers – Impulse Voltage Test System – HV Hipot Detail:
Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
Impulse voltage grade | 100kV-7200kV |
Standard lightning wave | 1.2±30%/50±20%µS |
Peak oscillation | <5% |
Standard switching wave | 250±20%/2500±60%µS |
Virtual front time of oscillating lightning wave | ≤15µS |
Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
The minimum output voltage | ≥10%Un |
Charging voltage instability | <±1% |
Synchronizing range | ≥20% |
Synchronous discharge error rate | <2% |
Ignition range | 10%~100% |
Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
Generator efficiency: lightning wave (no load) | ≥90% |
Time to chopping | 2~5µS |
Product detail pictures:



Related Product Guide:
"Based on domestic market and expand overseas business" is our development strategy for China High Quality Step Pulse Generator Suppliers – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: Philadelphia, Botswana, Algeria, Look forward to the future, we'll focus more on the brand building and promotion . And in the process of our brand global strategic layout we welcome more and more partners join us, work together with us based on mutual benefit. Let's develop market by fully utilizing our in depth advantages and strive for building.

Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
