China High Quality supplier protection relay tester Factory – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

China High Quality supplier protection relay tester Factory – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We constantly function like a tangible group to ensure that we can give you the very best high-quality and also the very best cost for Capacitance Effect, Capacitor Price, Winding Resistance Test, Seeing believes! We sincerely welcome the new customers abroad to set up business relationships and also expect to consolidate the relationships with the long-established customers.
China High Quality supplier protection relay tester Factory – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot Detail:

Features

● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode.

● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information;

● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high current to small current.

● The output part is controlled by DSP, which has fast calculation speed, strong real-time digital signal processing capability, transmission bandwidth and high-resolution D/A conversion. The output waveform has high precision, small distortion and good linearity. It adopts a large number of advanced technologies and precision component materials, and has carried out professional structural design. Therefore, the device is small in size, light in weight, full in function, easy to carry, and can be operated once start up, and the test is very convenient.

● It can complete a large number of large-scale complex verification work with high degree of automation. It can easily test and scan various protection settings, perform fault playback, store test data in real time, display vector graphics, and print reports online.

● There is an independent 110V and 220V dedicated adjustable DC power output for on-site inspection.

● The new generation GDJB-1200A tester is equipped with 10-way opening and 8-way opening, which is convenient for self-injection test. The input contact is compatible with an empty contact and 0~250V potential contacts, which can be intelligently and automatically recognized.

● Can perform a variety of complex calibration tasks, and can easily test and scan various protection settings for fault playback. Store test data in real time, display vector graphics, print reports, etc.

● The heat dissipation structure is designed reasonably, the hardware protection measures are reliable and perfect, and the power soft start function, software self-diagnosis and output blocking function are provided.

Specifications

AC Current Output
 
6-phase (RMS) 6*0~30A
3-phase (RMS) 3*0~60A
6-phase parallel current output (RMS) 0~180A
Allowable long time working value of phase current (RMS) 10A
Maximum output power of phase current 400VA
Allowable working hours @ max. output of 6-phase parallel current 10s
Accuracy ≤0.5A   ±2mA
>0.5A   0.2%
Frequency range (Fundamental wave) 0~1000Hz
Harmonic times 0~20 times
DC Current Output
 
Current output 0~±10A/phase;  0~±60A/6-pahse parallel
Accuracy  0.5%
Maximum output load voltage 20V
AC Voltage Output
 
Phase voltage output (RMS) 0~120V   Accuracy: 0.2%
Line voltage output (RMS) 0~240V
Phase voltage/Line voltage output power 80VA/100VA
Frequency range (Fundamental wave) 0~1000Hz
Harmonic times 1~20 times
DC Voltage Output
 
Phase voltage output amplitude 0~±160V    Accuracy: 0.5%
Line voltage output amplitude 0~±320V
Phase voltage/Line voltage output power 70VA/140VA
Binary
 
Binary input 10 channels
Idle contact 1~20mA, 24V
Potential contact access “0″: 0 ~+6V; “1″: +11 V ~+250 V
Binary output  8 pairs   DC: 220 V/0.2 A; AC: 220 V/0.5 A
Time Measuring Range  0.1ms~9999s        Measuring accuracy: <0.1mS
Dimension & Weight 480*360*200mm³       19kg 

Accessories

No.

Name

Description

Qty/Unit

Picture

1

Main Unit

GDJB-1200A

1set

GDJB-1200A Six Phase Relay Protection Test Set01

2

Fuse

2A

4 pieces

GDJB-1200A Six Phase Relay Protection Test Set010

10A

4 pieces

3

Power cord

 

1 piece

GDJB-1200A Six Phase Relay Protection Test Set09

4

Test wire

0.5m(red,yellow,green,black each 2 piece)

8 pieces

GDJB-1200A Six Phase Relay Protection Test Set08

5

Test wire 4 core

Black(red,yellow,green,black)-flat

2 pieces

GDJB-1200A Six Phase Relay Protection Test Set07

6

Test wire 4 core

Black(red,yellow,green,black)-circular

2 pieces

GDJB-1200A Six Phase Relay Protection Test Set06

7

Test wire

blue

1 piece

GDJB-1200A Six Phase Relay Protection Test Set05

8

Test wire

(white,coffee each 1 piece)

2 pieces

9

Test wire

red, green, yellow each 1 piece)

3 pieces

10

Test wire

black

2 pieces

11

Communication wire

 

1 piece

GDJB-1200A Six Phase Relay Protection Test Set04

14

Large test clamp

(red,yellow,green,black each 1 piece)

4 pieces

GDJB-1200A Six Phase Relay Protection Test Set03

15

Small test clamp

(yellow,green, each 4 pieces)

8 pieces

16

Small test clamp

(red,black each 5piece)

10 pieces

17

Illustration

(red,yellow,green,black each 2 pieces)

8 pieces

18

Test needle

(red,yellow,green,black each 3 pieces)

12 pieces

19

CD

 

1 copy

GDJB-1200A Six Phase Relay Protection Test Set02

20

QC pass

In English

1 copy

GDJB-1200A Six Phase Relay Protection Test Set011

21

Manual

In English

1 copy

GDJB-1200A Six Phase Relay Protection Test Set012

Product detail pictures:

China High Quality supplier protection relay tester Factory –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

China High Quality supplier protection relay tester Factory –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

China High Quality supplier protection relay tester Factory –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

China High Quality supplier protection relay tester Factory –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

China High Quality supplier protection relay tester Factory –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

China High Quality supplier protection relay tester Factory –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures


Related Product Guide:

We support our prospective buyers with ideal top quality merchandise and superior level provider. Becoming the specialist manufacturer in this sector, we have now attained abundant practical expertise in producing and managing for China High Quality supplier protection relay tester Factory – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot , The product will supply to all over the world, such as: India, Slovak Republic, Madras, We're your reliable partner in the international markets of our products and solutions. We focus on providing service for our clients as a key element in strengthening our long-term relationships. The continual availability of high grade solutions in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market. We're willing to cooperate with business friends from at home and abroad, to create a great future. Welcome to Visit our factory. Looking forward to have win-win cooperation with you.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Karl from Slovak Republic - 2017.09.09 10:18
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Jamie from Rwanda - 2018.02.12 14:52

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us