China High Quality Tan Delta Kit Factories – AC DC High Voltage Divider – HV Hipot
China High Quality Tan Delta Kit Factories – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
DC frequency (Hz) | <2 | |||||
AC frequency (Hz) | 30-300 | |||||
Accuracy | AC: 1.5%/DC: 1.0% | |||||
Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
Cable impedance(Ω) | 50 / 75 | |||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
Packing Medium | Polyurethane foaming agent | |||||
Operation temperature | 0℃-45℃ | |||||
Relative humidity | <85%RH, no condensation | |||||
Altitude | <1500m (or customized) | |||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:



Related Product Guide:
We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for China High Quality Tan Delta Kit Factories – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Brasilia, UK, Amsterdam, In the new century, we promote our enterprise spirit "United, diligent, high efficiency, innovation", and stick to our policy"basing on quality, be enterprising, striking for first class brand". We would take this golden opportunity to create bright future.

This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.

Send your message to us:
Write your message here and send it to us