We believe in: Innovation is our soul and spirit. Quality is our life. Shopper need is our God for Hv Testing Equipment, Tan Delta Testing For Power Transformer, Capacitance Voltage Meter, With a wide range, good quality, reasonable prices and stylish designs, our products are extensively used in this industries and other industries.
China High Quality Tension test Factory – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:

Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.

GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.

Features

● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.

Specification

Measuring range 0-200mN/m
Accuracy 0.1% of the reading±0.1 mN/m
Resolution 0.1mN/m
Sensitivity 0.1mN/m
Power supply AC220V±20%,50Hz±10%
Maximum power consumption 20W
Environmental temperature 10~30℃(25℃ is the best)
Environmental humidity ≤85% RH
Dimension 200×300×330(mm)
Weight 6kg

Product detail pictures:

China High Quality Tension test Factory –  GDZL-503 Automatic Interfacial Tension tester – HV Hipot detail pictures

China High Quality Tension test Factory –  GDZL-503 Automatic Interfacial Tension tester – HV Hipot detail pictures


Related Product Guide:

We usually continually offer you the most conscientious consumer services, along with the widest variety of designs and styles with finest materials. These initiatives include the availability of customized designs with speed and dispatch for China High Quality Tension test Factory – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Australia, Cambodia, Moldova, We have now 48 provincial agencies in the country. We also have stable cooperation with several international trading companies. They place order with us and export solutions to other countries. We expect to cooperate with you to develop a larger market.
  • Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Mandy from Gabon - 2018.09.23 17:37
    This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Betty from Namibia - 2017.04.28 15:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us