China High Quality Tension test kit Factories – GDND-800 Freezing Point Tester – HV Hipot
China High Quality Tension test kit Factories – GDND-800 Freezing Point Tester – HV Hipot Detail:
General Information
1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.
2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products.
Working conditions
1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment.
2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during operation.
3. When the instrument is not in use, it should be placed in a dry and ventilated place.
4. The power supply is single-phase three-wire system and must have a good grounding terminal.
5. The environmental conditions for the instrument use are: ambient temperature 5~30℃, humidity ≤85%, working power supply AC220V±10%, 50Hz.
Specification
Refrigerant | R13 R502 |
Cooling time | ≤100min (ambient temperature ≤30℃) |
Stop interval | >30min |
Stirring motor power | 22W * 2 |
Stirring motor allows temperature rise | 80℃ |
Power | 800W |
Voltage | 220V±10%, 50Hz±1Hz |
Temperature control range | room temperature ~ -70℃ |
Temperature control accuracy | ±0.5℃ |
Temperature display | LED |
Temperature sensor | Pt100 |
Timer | LED |
Product detail pictures:
![China High Quality Tension test kit Factories – GDND-800 Freezing Point Tester – HV Hipot detail pictures](https://cdn.globalso.com/hvhipot/GDND-800-Freezing-Point-Tester-.jpg)
Related Product Guide:
We take pleasure in an exceptionally excellent status between our buyers for our superb merchandise good quality, aggressive price tag and the greatest support for China High Quality Tension test kit Factories – GDND-800 Freezing Point Tester – HV Hipot , The product will supply to all over the world, such as: Mali, Italy, Leicester, Our product quality is one of the major concerns and has been produced to meet the customer's standards. "Customer services and relationship" is another important area which we understand good communication and relationships with our customers is the most significant power to run it as a long term business.
![5 Stars](https://www.hvhipot.com/admin/img/star-icon.png)
The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
![5 Stars](https://www.hvhipot.com/admin/img/star-icon.png)